Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If Energy Smart
power supplies are installed,
replace them with the High
Output power supplies to use
the components. See "Power
Supplies."
Alert! Redundant
memory disabled!
Memory
configuration
does not support
redundant
memory.
Memory Mirroring was
enabled in the system setup
program, but the current
configuration does not
support redundant memory.
A memory module may be
faulty.
Check the memory modules
for failure. See
"Troubleshooting System
Memory." Reset the memory
setting, if appropriate. See
"Using the System Setup
Program and UEFI Boot
Manager."
Alert! System
fatal error
during previous
boot.
An error caused the system
to reboot.
Check other system
messages for additional
information for possible
causes.
BIOS
MANUFACTURING
MODE detected.
MANUFACTURING
MODE will be
cleared before
the next boot.
System reboot
required for
normal
operation.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Table 1-2.
System Messages (continued)
Message
Causes
Corrective Actions