beautypg.com

Dell PowerVault NX3000 User Manual

Page 45

background image

About Your System

45

No boot device

available

Faulty or missing optical
drive subsystem, hard drive,
or hard-drive subsystem, or
no bootable USB key
installed.

Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting an Internal
SD Card," "T
roubleshooting
a USB Device,"
"Troubleshooting an Optical
Drive," and "Troubleshooting
a Hard Drive." See "Usi
ng the
System Setup Program and
UEFI Boot Manager" fo
r
information on setting the
order of boot devices.

No boot sector on

hard drive

Incorrect configuration
settings in System Setup
program, or no operating
system on hard drive.

Check the hard-drive
configuration settings in the
System Setup program. See
"Using the System Setup
Program and UEFI Boot
Manager." If necessary
, install
the operating system on your
hard drive. See your
operating system
documentation.

No timer tick

interrupt

Faulty system board.

See "Getting Help."

PCI BIOS failed

to install

PCIe device BIOS (Option
ROM) checksum failure
detected during shadowing.

Cables to expansion card(s)
loose; faulty or improperly
installed expansion card(s).

Reseat the expansion card(s).
Ensure that all appropriate
cables are securely connected
to the expansion card(s). If
the problem persists, see
"Troubleshooting Expansion
Cards."

PCIe Training

Error: Expected

Link Width is

x,

Actual Link Width

is

y.

Faulty or improperly
installed PCIe card in the
specified slot.

Reseat the PCIe card in the
specified slot number. See
"Troubleshooting Expansion
Cards." If the problem
persists, see "Getting Help."

Table 1-2.

System Messages (continued)

Message

Causes

Corrective Actions