Fabric Watch Administrator’s Guide

63

53-1002752-01

portThConfig command procedures

7

Signal loss

Monitors the
number of signal
loss errors.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Sync loss

Monitors the
number of loss of
synchronization
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range

Packet loss (VE_Port
only)

The number of
packets routed
through a port
exceeds the port
bandwidth.

Unit: Errors
Time Base: minute
Low: 0
High: 100
Buffer: 0

Below: 0
Above: 0

Informative
Informative

Protocol errors (PE)

Monitors the
number of primitive
sequence errors.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Received packets
(RXP)

Monitors the receive
rate, by percentage.

Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0

Below: 0
Above: 0

Informative
Informative

State changes (ST)

Monitors state
changes.

Unit: Changes
Time Base: minute
Low: 0
High: 50
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Transmitted packets
(TXP)

Monitors the
transmit rate, by
percentage.

Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0

Below: 0
Above: 0

Informative
Informative

Trunk utilization

The percent of
utilization for the
trunk at the time of
the last poll.

Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0

Below: 0
Above: 0

Informative
Informative

TABLE 17

E_Port class default settings (Continued)

Area

Description

Default threshold
settings

Default alarm settings

Threshold state