Physical port setting guidelines, Port class default settings, Table 16 – Dell POWEREDGE M1000E User Manual
Page 77
Fabric Watch Administrator’s Guide
57
53-1002752-01
Port class guidelines and default settings
7
Physical port setting guidelines
It is recommended that you use the default settings listed in
for most Port class areas.
Consider the Port class to be a superset containing the E_Port, FOP_Port, and FCU_Port
subclasses. If you make a change to a default setting for an area in the Port class, it applies to all of
the subclasses. This is convenient if you have determined that changes you plan to make to the
default settings for the subclasses are the same for certain areas. In this case, you only need to
make the changes to the Port class. Note, however, that if you make a change to one of the
subclasses, that change overrides the Port class setting.
Port class default settings
provides default settings for areas in the Port class.
TABLE 16
Port class default settings
Area
Description
Default threshold
settings
Default alarm settings
Threshold state
Cyclic redundancy
check (CRC)
Monitors the
number of CRC
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Invalid transmission
words (ITW)
Monitors the
number of invalid
words transmitted.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Class 3 discards
(C3TX_T0)
Class 3 discards
frames due to time
out or destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 2
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Link loss
Monitors the
number of link
failures.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative
Out_of_range
Signal loss
Monitors the
number of signal
loss errors.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
State changes (ST)
Monitors state
changes.
Unit: Changes
Time Base: minute
Low: 0
High: 50
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Sync loss
Monitors the
number of loss of
synchronization
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative