Dell PowerEdge M600 User Manual
Page 74
74
About Your System
Read fault.
Faulty diskette, diskette
drive, or optical drive.
Replace the diskette. Ensure
that the drive cable is
properly connected. See
"Troubleshooting USB
Devices" on page 183 or
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive(s)
installed in your system.
Remote
Configuration
update attempt
failed.
Blade could not
implement Remote
Configuration request.
Retry Remote
Configuration.
Sector not found.
Seek error.
Seek operation
failed.
Faulty diskette or hard
drive.
Replace the diskette. If the
problem persists, see
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive installed in
your system.
Shutdown failure.
Shutdown test failure.
Ensure that all memory
modules are properly
installed. See
"Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Spare bank
enabled.
Memory sparing enabled.
Information only.
The amount of
system memory has
changed.
Faulty memory module.
See "Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Information only, if you
have changed the memory
configuration.
Table 1-18.
Blade Messages (continued)
Message
Causes
Corrective Actions