Table 1-18.
Blade Messages
Message
Causes
Corrective Actions
Alert: DIMM_
n
and
DIMM_
n
must be
populated with a
matched set of
DIMMs if more than
1 DIMM is present.
The following
memory DIMMs have
been disabled.
The installed memory
configuration is invalid.
Ensure that the memory
modules are installed in
matched pairs. See "System
Memory" on page 105.
Alert! Node
Interleaving
disabled! Memory
configuration does
not support Node
Interleaving.
The installed memory
configuration does not
support node interleaving.
Install a memory
configuration that supports
node interleaving. See
"System Memory" on
page 105.
Alert! Redundant
memory disabled!
Memory
configuration does
not support
redundant memory.
The installed memory
configuration does not
support redundant
memory.
Install a memory
configuration that supports
redundant memory. See
"System Memory" on
page 105.
Disable the Redundant
Memory option in the
System Setup program. See
"Using the System Setup
Program" on page 79.
Alert! Redundancy
was previously
lost. Power cycle
required to
reconfigure
redundant memory.
Memory error.
Power cycle the blade.