Page 90

system --datacheck [--throttle <1-100>]
Use the Data Check --throttle option to specify the percentage of available DR Series system resources you want to use
when running Data Check scans when the other system operations (data ingest, Replication, and Cleaner processes)
are idle. The range is between 1 to 100 percent (%), and the default is 50%.
Description
Enables Data Check scans to use any percentage (1–100) of available DR Series system resource that you define. In this
example, 75% of the available DR Series system resources are selected.
Syntax
system --datacheck --throttle 75
Result
Data Check configuration successful: throttle set to 75%.
system --marker [--enable] [--disable]
Description
Enables or disables the marker detection status for all of the supported backup software used with a DR Series system
based on the option you use with the command.
Syntax
system --marker
Result
Please enter either --enable or --disable to change system-level marker
settings.
For more information about enabling or disable marker detection settings on a DR Series system, see
.
NOTE: To display the current status of the marker detection settings, use the DR Series system CLI command:
system --show --marker.
system --show --marker
Marker Detection : Enabled
system --marker [--disable]
Description
Disables the marker detection status for all supported backup software on a DR Series system. For example, the DR
Series system supports specific versions of data management application (DMA) software like NetBackup version 6.5
and 7.1, Backup Exec 2010 and 2012, and Veeam 5.7 and 6.0. For a complete list of the supported DMAs, see the
Dell DR
Series System Interoperability Guide
.
Syntax
system --marker --disable
Result
Successfully disabled system marker.
90