System --shutdown, System --upgrade, System --license [--validate] [--add – Dell PowerVault DR2000v User Manual
Page 84
Result
Please enter administrator password:
Broadcast message from root (pts/0) (Wed Jun 20 11:00:58 2012):
The system is going down for reboot NOW!
system --shutdown
Description
Shuts down a DR Series system when you use this command and provide the required password.
CAUTION: The system --shutdown command powers off the appliance on which the DR Series system software is
installed. Once the appliance is in a powered off state, you may only be able to power on the appliance in two
ways: at its physical location, or by using an iDRAC connection on the network.
Syntax
system --shutdown
Result
Please enter administrator password:
Broadcast message from root (pts/0) (Wed Oct 20 11:00:58 2012):
The system is being shutdown NOW!
system --upgrade
Description
Upgrades the version of the DR Series system software installed on a supported DR Series hardware appliance.
Syntax
system --upgrade
NOTE: To obtain the latest DR Series system upgrade image, navigate to the Dell Support website (dell.com/
support), enter your service tag or select your product, and download the latest DR Series system software
upgrade image file to the local system using WinSCP.
NOTE: Prior to performing a DR Series system CLI-based upgrade, make sure to download the DR Series system
upgrade image. To initiate a DR Series system software upgrade for Windows users using the DR Series system
CLI, the system software upgrade image file (in tar.gz format) is validated by the DR Series system, renamed to
DRSeries_payload.tar.gz, and transferred to a directory/store location known to the DR Series system.
When you use the DR Series system CLI system --upgrade command, the DR Series system looks in this known
directory/store location for the DRSeries_payload.tar.gz file, and starts the system software upgrade process.
NOTE: If the SSH session is lost for any reason during the upgrade process, this loss terminates the SSH session
and also terminates the upgrade process that was running. If this SSH session loss occurs during an upgrade
process and results in a terminated session, you should reboot the DR Series system and retry the system
software upgrade process.
system --license [--validate] [--add]
Description
Validates and installs the license for the external data storage you can add using the expansion shelf enclosures to the
base DR Series system. The expansion shelf licenses are based on the size of the expansion shelves; for details on
84