Dell PowerEdge 2800 User Manual
Page 17

E07F1
TEMP CPU n
HOT
Specified microprocessor is out of acceptable
temperature range and has halted operation.
See "
Troubleshooting System Cooling Problems
" in "Troubleshooting Your
System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "
Replacing a Processor
" in "Installing System
Components").
E07F4
POST CACHE
Faulty or improperly installed microprocessor.
See "
Troubleshooting the Microprocessors
" in "Troubleshooting Your System."
E07F4
POST CPU REG
E07F4
POST CPU SMI
SMI handler failed to initialize; faulty system
board.
See "
Getting Help
."
E07FA
TEMP CPU n
THERM
Specified microprocessor is out of acceptable
temperature range and is operating at a reduced
speed, or frequency.
See "
Troubleshooting System Cooling Problems
" in "Troubleshooting Your
System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "
Replacing a Processor
" in "Installing System
Components").
E0876
POWER PS n
No power available from the specified power
supply; specified power supply is improperly
installed or faulty.
See "
Troubleshooting Redundant Power Supplies
" in "Troubleshooting Your
System."
E0880
INSUFFICIENT
PS
Insufficient power is being supplied to the
system; power supplies are improperly installed,
faulty, or missing.
See "
Troubleshooting Redundant Power Supplies
" in "Troubleshooting Your
System."
E0CB2
MEM SPARE ROW
Correctable errors threshold was met in a
memory bank: errors were remapped to the
spare row.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0CF1
MBE DIMM Bank
n
Memory modules installed in the specified bank
are not the same type and size; faulty memory
module(s).
Ensure that both memory modules in the bank are the same type and size
and that they are properly installed. If the problem persists, see
"
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0CF1
POST MEM 64K
Parity failure in the first 64 KB of main memory.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0CF1
POST NO
MEMORY
Main-memory refresh verification failure.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0CF5
LOG DISABLE
SBE
Multiple single-bit errors on a single memory
module.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0D76
BP DRIVE FAIL
n
1x2 DRIVE
FAIL n
Faulty or improperly installed hard drive or RAID
controller.
See "
Troubleshooting SCSI Hard Drives
" "
Troubleshooting a RAID Controller
Card
, " and "
Troubleshooting the Integrated RAID Controller
" in
"Troubleshooting Your System."
E0F04
POST CMOS
CMOS write/read failure; faulty system board.
See "
Getting Help
."
E0F04
POST CPU
SPEED
Microprocessor speed control sequence failure.
See "
Getting Help
."
E0F04
POST DMA INIT
DMA initialization failure; DMA page register
write/read failure.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0F04
POST DMA REG
Faulty system board.
See "
Getting Help
."
E0F04
POST KYB
CNTRL
Faulty keyboard controller; faulty system board.
See "
Getting Help
."
E0F04
POST MEM RFSH
Main-memory refresh verification failure.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0F04
POST PIC REG
Master or slave PIC register test failure.
See "
Getting Help
."
E0F04
POST SHADOW
BIOS-shadowing failure.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E0F04
POST SHD TEST
Shutdown test failure.
E0F04
POST SIO
Super I/O chip failure; faulty system board.
See "
Getting Help
."
E0F04
POST TIMER
Programmable interval timer test failure; faulty
system board.
See "
Getting Help
."
E0F0B
POST ROM
CHKSUM
Faulty or improperly installed expansion card.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
E0F0C
VID MATCH CPU
n
Specified microprocessor is faulty, unsupported,
improperly installed, or missing.
See "
Troubleshooting the Microprocessors
" in "Troubleshooting Your System."
E10F3
LOG DISABLE
BIOS
BIOS disabled logging errors.
Check the SEL for details on the errors.
E13F2
IO CHANNEL
CHECK
Faulty or improperly installed expansion card;
faulty system board.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your System."
E13F4
PCI PARITY
E13F5
PCI SYSTEM
E13F8
CPU BUS INIT
Faulty or improperly installed microprocessor or
system board.
See "
Troubleshooting the Microprocessors
" in "Troubleshooting Your System."
If the problem persists, see "
Getting Help
."
E13F8
CPU BUS
PARITY
Faulty system board.
See "
Getting Help
."
E13F8
CPU MCKERR
Machine check error; faulty or improperly installed
microprocessor; faulty system board.
See "
Troubleshooting the Microprocessors
" in "Troubleshooting Your System."
E13F8
HOST BUS
Faulty system board.
See "
Getting Help
."
E13F8
HOST TO PCI
BUS
E13F8
MEM
CONTROLLER
Faulty or improperly installed memory module;
faulty system board.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System."
E1580
POWER CONTROL
Faulty system board.
See "
Getting Help
."