beautypg.com

Dell PowerEdge 2800 User Manual

Page 17

background image

E07F1

TEMP CPU n

HOT

Specified microprocessor is out of acceptable
temperature range and has halted operation.

See "

Troubleshooting System Cooling Problems

" in "Troubleshooting Your

System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "

Replacing a Processor

" in "Installing System

Components").

E07F4

POST CACHE

Faulty or improperly installed microprocessor.

See "

Troubleshooting the Microprocessors

" in "Troubleshooting Your System."

E07F4

POST CPU REG

E07F4

POST CPU SMI

SMI handler failed to initialize; faulty system
board.

See "

Getting Help

."

E07FA

TEMP CPU n

THERM

Specified microprocessor is out of acceptable
temperature range and is operating at a reduced
speed, or frequency.

See "

Troubleshooting System Cooling Problems

" in "Troubleshooting Your

System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "

Replacing a Processor

" in "Installing System

Components").

E0876

POWER PS n

No power available from the specified power
supply; specified power supply is improperly
installed or faulty.

See "

Troubleshooting Redundant Power Supplies

" in "Troubleshooting Your

System."

E0880

INSUFFICIENT

PS

Insufficient power is being supplied to the
system; power supplies are improperly installed,
faulty, or missing.

See "

Troubleshooting Redundant Power Supplies

" in "Troubleshooting Your

System."

E0CB2

MEM SPARE ROW

Correctable errors threshold was met in a
memory bank: errors were remapped to the
spare row.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0CF1

MBE DIMM Bank

n

Memory modules installed in the specified bank
are not the same type and size; faulty memory
module(s).

Ensure that both memory modules in the bank are the same type and size
and that they are properly installed. If the problem persists, see
"

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0CF1

POST MEM 64K

Parity failure in the first 64 KB of main memory.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0CF1

POST NO

MEMORY

Main-memory refresh verification failure.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0CF5

LOG DISABLE

SBE

Multiple single-bit errors on a single memory
module.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0D76

BP DRIVE FAIL

n

1x2 DRIVE

FAIL n

Faulty or improperly installed hard drive or RAID
controller.

See "

Troubleshooting SCSI Hard Drives

" "

Troubleshooting a RAID Controller

Card

, " and "

Troubleshooting the Integrated RAID Controller

" in

"Troubleshooting Your System."

E0F04

POST CMOS

CMOS write/read failure; faulty system board.

See "

Getting Help

."

E0F04

POST CPU

SPEED

Microprocessor speed control sequence failure.

See "

Getting Help

."

E0F04

POST DMA INIT

DMA initialization failure; DMA page register
write/read failure.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0F04

POST DMA REG

Faulty system board.

See "

Getting Help

."

E0F04

POST KYB

CNTRL

Faulty keyboard controller; faulty system board.

See "

Getting Help

."

E0F04

POST MEM RFSH

Main-memory refresh verification failure.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0F04

POST PIC REG

Master or slave PIC register test failure.

See "

Getting Help

."

E0F04

POST SHADOW

BIOS-shadowing failure.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E0F04

POST SHD TEST

Shutdown test failure.

E0F04

POST SIO

Super I/O chip failure; faulty system board.

See "

Getting Help

."

E0F04

POST TIMER

Programmable interval timer test failure; faulty
system board.

See "

Getting Help

."

E0F0B

POST ROM

CHKSUM

Faulty or improperly installed expansion card.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

E0F0C

VID MATCH CPU

n

Specified microprocessor is faulty, unsupported,
improperly installed, or missing.

See "

Troubleshooting the Microprocessors

" in "Troubleshooting Your System."

E10F3

LOG DISABLE

BIOS

BIOS disabled logging errors.

Check the SEL for details on the errors.

E13F2

IO CHANNEL

CHECK

Faulty or improperly installed expansion card;
faulty system board.

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

E13F4

PCI PARITY

E13F5

PCI SYSTEM

E13F8

CPU BUS INIT

Faulty or improperly installed microprocessor or
system board.

See "

Troubleshooting the Microprocessors

" in "Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

E13F8

CPU BUS

PARITY

Faulty system board.

See "

Getting Help

."

E13F8

CPU MCKERR

Machine check error; faulty or improperly installed
microprocessor; faulty system board.

See "

Troubleshooting the Microprocessors

" in "Troubleshooting Your System."

E13F8

HOST BUS

Faulty system board.

See "

Getting Help

."

E13F8

HOST TO PCI

BUS

E13F8

MEM

CONTROLLER

Faulty or improperly installed memory module;
faulty system board.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

E1580

POWER CONTROL

Faulty system board.

See "

Getting Help

."