Bus#nn/Dev#nn/Funcn
Expected Link Width is n
Actual Link Width is n
PCIe card or expansion-card
cage.
Expansion-Card Cage
" and "
Expansion Cards
" If the problem persists, see
"
Getting Help
."
PCIe Degraded Link Width Error: Slot n
Expected Link Width is n
Actual Link Width is n
Faulty or improperly installed
PCIe card in the specified
slot number.
Reseat the PCIe card in the specified slot number. See "
Expansion Cards
." If
the problem persists, see "
Getting Help
."
PCIe Training Error: Embedded
Bus#nn/Dev#nn/Funcn
Faulty or improperly installed
PCIe card or expansion-card
cage.
Reseat the PCIe cards and the expansion-card cage. See "
Installing the
Expansion-Card Cage
" and "
Expansion Cards
." If the problem persists, see
"
Getting Help
."
PCIe Training Error: Slot n
Faulty or improperly installed
PCIe card in the specified
slot number.
Reseat the PCIe card in the specified slot number. See "
Expansion Cards
." If
the problem persists, see "
Getting Help
."
Plug & Play Configuration Error
Error encountered in
initializing PCI device; faulty
system board.
Install the NVRAM_CLR jumper and reboot the system. See
Figure A
-2
for
jumper location. Check for a BIOS update. If the problem persists, see
"
Troubleshooting Expansion Cards
" in "Troubleshooting Your System." If the
problem persists, see "
Getting Help
."
Read fault
Requested sector not found
Faulty diskette, diskette
drive, optical drive, or hard
drive.
Replace the diskette. Ensure that the diskette, optical, and hard-drive cables
are properly connected. See "
Troubleshooting a Diskette Drive
,"
"
Troubleshooting an Optical Drive
," or "
Troubleshooting SCSI Hard Drives
," in
"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.
Remote Configuration update attempt failed
System could not implement
Remote Configuration
request.
Retry Remote Configuration.
ROM bad checksum = address
Faulty or improperly installed
expansion card.
Remove and reseat the expansion cards. See "
Troubleshooting Expansion
Cards
" in "Troubleshooting Your System."
Sector not found
Seek error
Seek operation failed
Faulty diskette or hard drive. Replace the diskette. If the problem persists, see
Troubleshooting SCSI Hard
Drives
" in "Troubleshooting Your System" for the appropriate drive installed in
your system.
Shutdown failure
Shutdown test failure.
Ensure that all memory modules are properly installed. See "
Troubleshooting
System Memory
" in "Troubleshooting Your System." If the problem persists,
see "
Getting Help
."
Spare bank enabled
Memory spare bank enabled. You can enable memory spare bank using the System Setup program if the
memory is configured to support this feature. For more information, see
"
General Memory Module Installation Guidelines
" in "Installing System
Components," and Using the System Setup Program" in your User's Guide.
The amount of system memory has changed.
Faulty memory module.
See "
Troubleshooting System Memory
" in "Troubleshooting Your System." If
the problem persists, see "
Getting Help
."
Information only, if you have
changed the memory
configuration.
Time-of-day clock stopped
Faulty battery; faulty system
board.
See "
Troubleshooting the System Battery
" in "Troubleshooting Your System."
If the problem persists, see "
Getting Help
."
Time-of-day not set - please run SETUP
program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date settings See "Using the System Setup Program" in
your User's Guide. If the problem persists, see "
Troubleshooting the System
Battery
" in "Troubleshooting Your System."
Timer chip counter 2 failed
Faulty system board.
See "
Getting Help
."
Unsupported RAID key detected.
A RAID key intended for use
with another system is
installed.
Replace the RAID key.
Unexpected interrupt in protected mode
Faulty or improperly installed
memory modules or faulty
system board.
Ensure that all memory modules are properly installed. See "
General Memory
Module Installation Guidelines
" in "Installing System Components." If the
problem persists, see "
Troubleshooting System Memory
" in "Troubleshooting
Your System." If the problem persists, see "
Getting Help
."
Unsupported CPU combination
Mismatched processors are
installed.
Processor is not supported
by the system.
Replace a microprocessor so that both microprocessors match. See "Adding or
Replacing a Microprocessor" in "Installing System Components."
Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "
Replacing a
Processor
" in "Installing System Components."
Unsupported CPU stepping detected
Processor is not supported
by the system.
Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "
Replacing a
Processor
" in "Installing System Components."
Utility partition not available
during POST, but no utility
partition exists on the boot
hard drive.
Create a utility partition on the boot hard drive. See "Using the Dell
OpenManage Server Assistant CD" in your User's Guide.
Warning: Detected mode change from RAID to
SCSI x of the embedded RAID subsystem.
Type of controller has
changed from optional RAID
to SCSI since previous
system boot.
Back up information on the hard drives before changing the type of controller
used with the drives.
Warning: Detected mode change from SCSI to
RAID x of the embedded RAID subsystem.
Type of controller has
changed from SCSI to
optional RAID since previous
system boot.
Back up information on the hard drives before changing the type of controller
used with the drives.