beautypg.com

Dell PowerEdge 2800 User Manual

Page 20

background image

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

PCIe card or expansion-card
cage.

Expansion-Card Cage

" and "

Expansion Cards

" If the problem persists, see

"

Getting Help

."

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed
PCIe card in the specified
slot number.

Reseat the PCIe card in the specified slot number. See "

Expansion Cards

." If

the problem persists, see "

Getting Help

."

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

Faulty or improperly installed
PCIe card or expansion-card
cage.

Reseat the PCIe cards and the expansion-card cage. See "

Installing the

Expansion-Card Cage

" and "

Expansion Cards

." If the problem persists, see

"

Getting Help

."

PCIe Training Error: Slot n

Faulty or improperly installed
PCIe card in the specified
slot number.

Reseat the PCIe card in the specified slot number. See "

Expansion Cards

." If

the problem persists, see "

Getting Help

."

Plug & Play Configuration Error

Error encountered in
initializing PCI device; faulty
system board.

Install the NVRAM_CLR jumper and reboot the system. See

Figure A

-2

for

jumper location. Check for a BIOS update. If the problem persists, see
"

Troubleshooting Expansion Cards

" in "Troubleshooting Your System." If the

problem persists, see "

Getting Help

."

Read fault

Requested sector not found

Faulty diskette, diskette
drive, optical drive, or hard
drive.

Replace the diskette. Ensure that the diskette, optical, and hard-drive cables
are properly connected. See "

Troubleshooting a Diskette Drive

,"

"

Troubleshooting an Optical Drive

," or "

Troubleshooting SCSI Hard Drives

," in

"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.

Remote Configuration update attempt failed

System could not implement
Remote Configuration
request.

Retry Remote Configuration.

ROM bad checksum = address

Faulty or improperly installed
expansion card.

Remove and reseat the expansion cards. See "

Troubleshooting Expansion

Cards

" in "Troubleshooting Your System."

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive. Replace the diskette. If the problem persists, see

Troubleshooting SCSI Hard

Drives

" in "Troubleshooting Your System" for the appropriate drive installed in

your system.

Shutdown failure

Shutdown test failure.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

" in "Troubleshooting Your System." If the problem persists,

see "

Getting Help

."

Spare bank enabled

Memory spare bank enabled. You can enable memory spare bank using the System Setup program if the

memory is configured to support this feature. For more information, see
"

General Memory Module Installation Guidelines

" in "Installing System

Components," and Using the System Setup Program" in your User's Guide.

The amount of system memory has changed.

Faulty memory module.

See "

Troubleshooting System Memory

" in "Troubleshooting Your System." If

the problem persists, see "

Getting Help

."

 

Information only, if you have
changed the memory
configuration.

 

Time-of-day clock stopped

Faulty battery; faulty system
board.

See "

Troubleshooting the System Battery

" in "Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

Time-of-day not set - please run SETUP

program

Incorrect Time or Date
settings; faulty system
battery.

Check the Time and Date settings See "Using the System Setup Program" in
your User's Guide. If the problem persists, see "

Troubleshooting the System

Battery

" in "Troubleshooting Your System."

Timer chip counter 2 failed

Faulty system board.

See "

Getting Help

."

Unsupported RAID key detected.

A RAID key intended for use
with another system is
installed.

Replace the RAID key.

Unexpected interrupt in protected mode

Faulty or improperly installed
memory modules or faulty
system board.

Ensure that all memory modules are properly installed. See "

General Memory

Module Installation Guidelines

" in "Installing System Components." If the

problem persists, see "

Troubleshooting System Memory

" in "Troubleshooting

Your System." If the problem persists, see "

Getting Help

."

Unsupported CPU combination

Mismatched processors are
installed.

Processor is not supported
by the system.

Replace a microprocessor so that both microprocessors match. See "Adding or
Replacing a Microprocessor" in "Installing System Components."

Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "

Replacing a

Processor

" in "Installing System Components."

Unsupported CPU stepping detected

Processor is not supported
by the system.

Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "

Replacing a

Processor

" in "Installing System Components."

Utility partition not available

key was pressed
during POST, but no utility
partition exists on the boot
hard drive.

Create a utility partition on the boot hard drive. See "Using the Dell
OpenManage Server Assistant CD" in your User's Guide.

Warning: Detected mode change from RAID to

SCSI x of the embedded RAID subsystem.

Type of controller has
changed from optional RAID
to SCSI since previous
system boot.

Back up information on the hard drives before changing the type of controller
used with the drives.

Warning: Detected mode change from SCSI to

RAID x of the embedded RAID subsystem.

Type of controller has
changed from SCSI to
optional RAID since previous
system boot.

Back up information on the hard drives before changing the type of controller
used with the drives.