Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B, DIMM3_A and

DIMM3_B match identically in size, speed,

and rank.

pairs of memory modules are
detected

Memory Module Installation Guidelines

" in "Installing System Components."

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B only

support single rank DIMMs. Remove the dual

rank DIMMs from slots DIMM3_A and DIMM3_B.

Dual-rank memory modules
are installed in slots
DIMM3_A and DIMM3_B.

Ensure that only single-rank memory modules are installed in slots DIMM3_A
and DIMM3_B. See "

General Memory Module Installation Guidelines

" in

"Installing System Components."

Error: Incorrect memory configuration.

Move DIMM3_A and DIMM3_B into DIMM2_A and

DIMM2_B.

Memory modules are not
installed in consecutive
banks.

Move memory modules from slots DIMM3_A and DIMM3_B into DIMM2_A and
DIMM2_B. See "

General Memory Module Installation Guidelines

" in "Installing

System Components."

Error: Incorrect memory configuration.

Swap the DIMMs in slots DIMM1_A and

DIMM1_B with DIMMs in slots DIMM2_A and

DIMM2_B.

If dual-rank memory
modules are installed in the
system, they must be
installed in slots DIMM1_A
and DIMM1_B.

Swap memory modules in slots DIMM2_A and DIMM2_B with modules in
DIMM1_A and DIMM1_B. See "

General Memory Module Installation Guidelines

"

in "Installing System Components."

 

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B must be

empty if dual rank memory DIMMS are in

slots DIMM2_A and DIMM2_B.

Memory modules are
installed in bank 3. Dual

-

rank memory modules are
installed in banks 1 and 2.

Remove memory modules from slots DIMM3_A and DIMM3_B. See "

General

Memory Module Installation Guidelines

" in "Installing System Components."

 

Error: More than one RAC detected, system

halted.

Two RACs are installed, or
faulty or improperly installed
RAC.

Ensure that only one RAC is installed. Ensure that the RAC is properly
installed. See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your

System," or "

Installing a RAC Card

" in "Installing System Components."

Error: Remote Access Card initialization

failure.

Faulty or improperly installed
RAC.

Ensure that the RAC is properly installed. See "

Troubleshooting Expansion

Cards

" in "Troubleshooting Your System," or "

Installing a RAC Card

" in

"Installing System Components."

 

Error 8602: Auxiliary device failure.

Verify that the keyboard and mouse are

securely attached to correct connectors.

Loose or improperly
connected mouse or
keyboard cable; faulty
mouse or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

."

General failure

Operating system corrupted
or improperly installed.

Reinstall the operating system.

Keyboard controller failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists,
replace the keyboard. If the problem persists, see "

Getting Help

."

 

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

 

 

Faulty system board. See "

Getting Help

."

Manufacturing mode detected

System is incorrectly
configured.

After the message appears during system boot, press to turn off
manufacturing mode.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address, read

value expecting value

Faulty or improperly installed
memory modules, or faulty
system board.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

" in "Troubleshooting Your System." If the problem persists,

see "

Getting Help

."

Memory mirroring enabled

Memory mirroring enabled

You can enable memory mirroring using the System Setup program if the
memory is configured to support mirroring. For more information, see
"

General Memory Module Installation Guidelines

" in "Installing System

Components," and Using the System Setup Program" in your User's Guide.

Memory tests terminated by keystroke

The spacebar was pressed
during POST to terminate
the memory test.

Information only.

No boot device available

Faulty or missing diskette
drive, optical drive, or hard
drive.

 

Check the Integrated Devices configuration settings in the System Setup
program. See "Using the System Setup Program" in your User's Guide. Ensure
that either SCSI Controller, Diskette Controller, or IDE CD-ROM Controller
is enabled. If the system is booting from a SCSI controller, ensure that the
controller is properly connected. If the problem persists, replace the drive.
See "

Installing Drives

."

No boot sector on hard-disk drive

An operating system is not
on the hard drive.

Check the hard-drive configuration settings in the System Setup program.
See "Using the System Setup Program" in your User's Guide.

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion
card(s); faulty or improperly
installed expansion card.

Ensure that all appropriate cables are securely connected to the expansion
cards. See "

Troubleshooting Expansion Cards

," in "Troubleshooting Your

System."

PCIe Degraded Link Width Error: Embedded

Faulty or improperly installed Reseat the PCIe cards and the expansion-card cage. See "

Installing the