SCSI Hard-Drive Indicator Codes

If RAID is activated, two indicators on each of the hard-drive carriers provide information on the status of the SCSI hard drives. RAID can be enabled either by
activating the system's integrated RAID controller or by using a RAID expansion card connected to the backplane. See

Figure 2

-3

and

Table 2

-3

. The

SCSI backplane firmware controls the drive power

-on/fault indicator.

 

Figure 2-3. SCSI Hard-Drive Indicators

Table 2

-3

lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard drive fails, the "drive

failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive ready for
insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by the "drive online"
pattern.

 

Table 2-3. Hard-Drive Indicator Patterns 

NOTE:

If a RAID controller is not installed, only the "drive online" indicator pattern appears. The drive-activity indicator also blinks when the drive is

being accessed.

 

Condition

 

Indicator Pattern

Identify drive

The green power-on/fault indicator blinks four times per second.

Drive being prepared for removal

The green power-on/fault indicator blinks two times per second.

Drive ready for insertion or removal Both drive indicators are off.

Drive being prepared for operation The green power-on/fault indicator is on.

Drive predicted failure

The power-on/fault indicator slowly blinks green, amber, and off.

Drive failed

The amber power-on/fault indicator blinks four times per second.

Drive rebuilding

The green power-on/fault indicator blinks slowly.

Drive online

The green power-on/fault indicator is on.