beautypg.com

Dell POWEREDGE R805 User Manual

Page 10

background image

Configuration. Please wait...

detected and is being processed.

BIOS Update Attempt Failed!

Remote BIOS update attempt failed.

Retry the BIOS update. If problem persists, see

Getting Help

.

Caution! NVRAM_CLR jumper is installed

on system board.

NVRAM_CLR jumper is installed. CMOS has
been cleared.

Remove NVRAM_CLR jumper. See

Figure 6

-1

for jumper

location.

CPUs with different cache sizes

detected!

Microprocessors with different cache sizes are
installed.

Ensure that all microprocessors have the same cache size and
that they are properly installed. See

Processors

.

Decreasing available memory

Faulty or improperly installed memory modules. See

Troubleshooting System Memory

.

Error: Incorrect memory configuration

CPU n

The DIMM group for CPU n is incorrectly
configured and caused the system to halt.

See

General Memory Module Installation Guidelines

for memory

configuration information. If the problem persists, see

Troubleshooting System Memory

.

!!*** Error: Remote Access Controller

initialization failure *** RAC virtual

USB devices may not be available...

Remote Access Controller initialization failure

Ensure that the Remote Access Controller is properly installed.
See

Installing a RAC Card

.

Gate A20 failure

Faulty keyboard controller; faulty system
board.

See

Getting Help

.

General failure

The operating system is unable to carry out
the command.

This message is usually followed by specific information. Note
the information, and take the appropriate action to resolve the
problem.

HyperTransport error caused a system

reset! Please check the system event

log for details!

A fatal system error occurred and caused the
system to reboot.

Check the SEL for information that was logged during the
error. See the applicable troubleshooting section in

Troubleshooting Your System

for any faulty components

specified in the SEL.

Invalid NVRAM configuration, Resource

Re-allocated

System detected and corrected a resource
conflict.

No action is required.

Invalid PCIe card found in the

Internal_Storage slot!

The system halted because an invalid PCIe
expansion card is installed in the dedicated
storage controller slot.

Remove the PCIe expansion card and install either the internal
SAS controller in the dedicated slot.

Keyboard Controller failure

Faulty keyboard controller; faulty system board See

Getting Help

.

Manufacturing mode detected

System is in manufacturing mode.

Reboot to take the system out of manufacturing mode.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at

address, read value expecting value

Memory write/read failure at address,

read value expecting value

Faulty or improperly installed memory modules. See

Troubleshooting System Memory

.

Memory tests terminated by keystroke.

POST memory test terminated by pressing the
spacebar.

Information only.

No boot device available

Faulty or missing optical drive subsystem, hard
drive, or hard-drive subsystem, or no bootable
USB key installed.

Use a bootable USB key, CD, or hard drive. If the problem
persists, see

Troubleshooting an SD Card or Internal USB Key

and

Troubleshooting a Hard Drive

. See

Using the System Setup

Program

for information on setting the order of boot devices.

No boot sector on hard drive

Incorrect configuration settings in System
Setup program, or no operating system on
hard drive.

Check the hard-drive configuration settings in the System
Setup program. See

Using the System Setup Program

. If

necessary, install the operating system on your hard drive.
See your operating system documentation.

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Optical drive not found

Cable is not properly seated, or drive missing.

See

Troubleshooting an Optical Drive

.

PCI BIOS failed to install

PCIe device BIOS (Option ROM) checksum
failure detected during shadowing.

Cables to expansion card(s) loose; faulty or
improperly installed expansion card(s).

Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s). If the
problem persists, see

Troubleshooting Expansion Cards

.

PCIe Degraded Link Width Error:

Embedded device

Expected Link Width is n

Actual Link Width is n

Faulty system board or riser board.

See

Getting Help

.

PCIe Degraded Link Width Error:

Integrated device

Expected Link Width is n

Actual Link Width is n

The specified PCIe device is faulty or
improperly installed.

For a SAS controller daughter card, reseat the card in the
dedicated PCIe connector. See

Installing a SAS Controller

Daughter Card

. If the problem persists, see

Getting Help

.

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card in the
specified slot.

Reseat the PCIe card in the specified slot number. See

Expansion Cards

. If the problem persists, see

Getting Help

.

PCIe Training Error: Embedded device

Faulty system board or riser board.

See

Getting Help

.