Dell

Latitude™ XT2 XFR Service Manual

Page 17 of 94

Version A00-01


After the test is complete, the results are displayed as illustrated below.



Use this table to define the result codes.

Digitizer Self Test Result Codes

Code

Test

Error Details

Symptoms

7

A-trigs
connectivity

Digitizer analog
processor fail

Digitizer is unable to initialize or read samples from analog
processor. No pen or touch position is reported.

11

Stylus excitation

No pen excitation

Signals received during the stylus excitation test are below
certain limit. Pen may be not functional or detected in tip
only.

14

Sensor Antenna
disconnects

Digitizer grid
disconnect

There are disconnected lines. Pen or touch may be
malfunctioning in a specific physical display area.

15

Sensor Antenna
shorts

Digitizer grid
shortcut

There are shorted lines. Pen or touch may be malfunctioning
in a specific physical display area.

18

Channel
imbalance

Digitizer channel
degraded

There is an unbalanced channel. Pen or touch may be
malfunctioning in a specific physical display area.

19

Capacitor
calibration

Digitizer
calibration
degraded

The calibration capacitor in a certain channel is set to
minimal or maximum value. Pen or touch may be
malfunctioning in a specific physical display area.

47

Internal Firmware
Error

Internal
Firmware Error

Firmware resource problem in executing diagnostics.
Diagnostics tool is not functional.

48

Critical
Malfunction

Device Error

Critical malfunction was detected, test cannot continue.