Canon COLORPASS-Z6000 PS-NX6000 User Manual
Page 66
![background image](/manuals/60849/66/background.png)
4-20
4
Service Procedures
T
O
REMOVE
THE
USER
INTERFACE
BOARD
N
OTE
:
The UIB is attached to a removable bracket. You do not need to remove the
bracket when removing or replacing the UIB.
1.
Shut down and open the ColorPASS (see page 4-4 and page 4-5).
2.
Remove the front panel from the chassis (see page 4-9).
3.
Remove three of the four screws that secure the UIB to the media bracket.
4.
While supporting the UIB, remove the fourth screw.
F
IGURE
4-12
Removing/replacing the user interface board
5.
Disconnect the UIB cable from the connector on the UIB.
Press outward on the connector levers on each side of the connector (see Figure 4-13),
and then detach the connector. Avoid pulling on the cable.
F
IGURE
4-13
Detail of ribbon cable connector
6.
Place the board in an antistatic bag.
Screws
(2 of 4)
UIB
UIB cable
Mounting post on bracket
(1 of 4)
Connector levers