Monitor Material Configuration

The DICKEY-john IntelliAG monitor reads meter shaft
speeds and can report pounds/acre (or kg/Ha) planted.

In order to report accurately, the monitor requires several
inputs. Inputs that rarely change were entered during drill
setup. Inputs specific to particular materials (seed or fer-
tilizer) need to be entered when those materials are first
used, and when changed.

Material Configuration Setup Screen
for Seeds

Type” - This must be set to “Gran Seed Monitor” to con-
figure for seeds.

Density Units” - In metric mode this is always kg/liter.
If configured for “U.S.” mode (U.S. customary units), this
is pounds-per-bushel or pounds-per-cubic-foot.

Density” - This is the density of seed being planted.
Obtain this information from the material container/sup-
plier. If unknown, use the value specified in the rate
chart.

Total Number of Towers” - This is the number of pri-
mary hoses coming off the rear meter box
(this is always 4 for NTA907HD or NTA3007HD).

Calibration Constant” - This is the number listed in the
seed rate charts for the rate you are planting or the num-
ber obtained from running the calibration routine for your
specific seed.

Material Configuration Setup Screen for
Fertilizer

Type” - This must be set to “Gran Fert Monitor” to con-
figure for fertilizer.

Density” - Enter the density of Fertilizer being applied,
in kilograms-per-liter (pounds-per-cubic-foot). Obtain this
information from the material container/supplier. If
unknown, use the value specified in the rate chart.

Total Number of Towers” - This is the number of pri-
mary hoses coming off the rear meter box
(this is always 4 for NTA907HD or NTA3007HD).

Calibration Constant” - This is the number listed in the
seed rate charts for the rate you are planting or the num-
ber obtained from running the calibration routine for your
specific fertilizer.

See the DICKEY-john Quick Start guide for
more detailed instructions.

Null4:

25421

Note: Always enter Density Units before entering the

Density value. Changing the value of Density