Fan general information – Great Plains NTA3007HD Operator Manual User Manual
Page 64
60 NTA907HD or NTA3007HD
166-207M
04/04/2011
Fan General Information
The hydraulic fan supplies the air stream that carries
materials from the meters, through the primary hoses to
the towers, then to the secondary hoses to the rows.
The fan needs to be running in the correct direction, and
within a narrow speed range, to reliably deliver material
at your calibrated rates.
Refer to Figure 68
If an auger is installed on the drill, it shares the hydraulic
circuit with the fan.
1.
Turn on the seed monitor. Configure it for the materi-
als and rates planned. Set reasonable alarm levels
for low flow rate alerts.
2.
If no auger is installed, skip to step 5.
3.
Set the fan/auger hydraulic circuit to neutral for
setup.
4.
Check the fan/auger selector valve is set to FAN.
This valve is located inside the right rear of the main-
frame.
5.
With the tractor engine at low rpm, slowly Extend the
lever for the circuit. Bring the fan up to recommended
speed (page 83). Let the fan warm up for 15 minutes
before planting.
6.
Lower the drill 1.5 - 3m (5-10ft) before planting is to
begin. It takes a few seconds for seed to travel from
the meters to the rows.
Always engage the fan with the tractor at a low engine speed.
Engaging the fan when the tractor is at high speed may cause
fan damage.
Do not reverse hydraulic flow with the fan running.
7.
Mind the seed monitor console for seed rate alerts.
An apparent blockage, or irregular or no flow across
the drill, may be an indication that the fan is running
backwards.
8.
Leave the fan running during field turns. Material flow
is shut off when the openers are raised.
9.
At the end of application, raise openers. Stop mate-
rial flow before shutting off the fan.
10. Shut off the fan by carefully moving the circuit lever
to Float or Neutral. Avoid moving the lever into
Retract.
Null4:
Figure 68
Fan/Auger Selector Valve
29525
Null4:
Null4:
Null4:
Null4:
Note: If the fan plumbing or hitch hookup is reversed, air
flow rate will be very low or zero. If you are unable
to reach 3000 rpm, check hose connections.
Note: Fan speed is monitored and reported by the seed
monitor, but is manually controlled. The optimum
rate depends on the seed type, any treatments.
“Fan Speed Adjustments” on page 83 for further
information.
Fan Setup: Hydraulic Circuit Operation
Lift
Fan,
Auger
Fold, Tilt,
Marker
Transport
Hooks
Extend
Float or
Neutral
Neutral
Neutral
Null4:
Planting: Hydraulic Circuit Operation
Lift
Fan,
Auger
Fold, Tilt,
Marker
Transport
Hooks
Retract
Extend
Neutral
Neutral
Null4:
End Planting: Hydraulic Circuit Operation
Lift
Fan,
Auger
Fold, Tilt,
Marker
Transport
Hooks
Extend
Float or
Neutral
Neutral
Neutral