Great Plains NP30A 30-foot Operator Manual User Manual
Page 93
Great Plains Manufacturing, Inc.
Adjustments
89
2014-05-20
407-502M
7.
Set tractor remote circuit for unfold. Lock lever for
continuous operation.
8.
At the pressure reducing valve
, release the lock
disc
.
9.
Adjust the knob
for an initial value of 800 psi on
the gauge
. Tighten the lock disc.
10. At the bypass valve
, release the lock disc
.
Adjust the bypass valve knob counter-clockwise until
the pressure reading just begins to fall from the value
set at step 9. Turn the knob clockwise
1
⁄
4
turn.
Tighten the lock disc.
11. Observe applicator operation, and re-adjust
down-pressure as necessary after oil warm-up.
Repeat step 7 through step 10. The bypass valve
needs to be closed prior to any adjustment to
increase weight transfer.
Figure 70
Weight Transfer Adjustment
32041
2
3
6
5
4
7
8
1
2
6
7
8
3
4