NP30A or NP40A

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-502M

Table of Contents

Index

2014-05-20

NH

3

Consumption

Too High (but no
alarms)

Incorrect console setup

Re-check METER CAL and BOOM CAL.

Field size different.

After ruling out metering problems, re-check geography.

Excessive overlap

Gap between opposing pass end trenches should be one
row space (e.g. 30in). Also check tracks for unintended
re-applications, particularly if relying on GPS mapping.

Tank or system Leak

Suspend application. Carefully approach applicator and
nurse tank from up-wind. Check for leaks in

Flow meter malfunction

Consult dealer.

Rows Not Fertilized

Check for plugged row-unit
tube

Stop application per page 76. Lift applicator and inspect
knives or tines. Clear any plugging per “Clearing Plugged
Knives or Tines
” on page 112.

Failed or malfunctioning
aftermarket section control.

Consult system supplier documentation.

No Fertilizer Flow

Strainer plugged

Close all valves. Inspect strainer (page 119). Clean screen
and magnets as needed.

Material run-out

Check tank level.

Temperature too low

Wait for warmer conditions.

On/Off solenoid valve failure
or open circuit.

Suspend operation (page 75).
Close emergency shut-off valve.
Discharge line from emergency shut-off valve to knives or
tines.
Wait for applicator to be safe to approach.
Check harness connections and fuses.
Use console SELF-TEST mode to command Raven valves
open. Check valve ball indicators at valves.

Metering System Troubleshooting

Problem

Cause

Solution