Great Plains NP30A 30-foot Operator Manual User Manual
Page 108

104
NP30A or NP40A
Great Plains Manufacturing, Inc.
407-502M
2014-05-20
NH
3
Consumption
Too High (but no
alarms)
Incorrect console setup
Re-check METER CAL and BOOM CAL.
Field size different.
After ruling out metering problems, re-check geography.
Excessive overlap
Gap between opposing pass end trenches should be one
row space (e.g. 30in). Also check tracks for unintended
re-applications, particularly if relying on GPS mapping.
Tank or system Leak
Suspend application. Carefully approach applicator and
nurse tank from up-wind. Check for leaks in
Flow meter malfunction
Consult dealer.
Rows Not Fertilized
Check for plugged row-unit
tube
Stop application per page 76. Lift applicator and inspect
knives or tines. Clear any plugging per “Clearing Plugged
Knives or Tines” on page 112.
Failed or malfunctioning
aftermarket section control.
Consult system supplier documentation.
No Fertilizer Flow
Strainer plugged
Close all valves. Inspect strainer (page 119). Clean screen
and magnets as needed.
Material run-out
Check tank level.
Temperature too low
Wait for warmer conditions.
On/Off solenoid valve failure
or open circuit.
Suspend operation (page 75).
Close emergency shut-off valve.
Discharge line from emergency shut-off valve to knives or
tines.
Wait for applicator to be safe to approach.
Check harness connections and fuses.
Use console SELF-TEST mode to command Raven valves
open. Check valve ball indicators at valves.
Metering System Troubleshooting
Problem
Cause
Solution