beautypg.com

Great Plains NP30A 30-foot Operator Manual User Manual

Page 109

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

105

2014-05-20

Table of Contents

Index

407-502M

General Application Troubleshooting

Problem

Cause

Solution

Excess
Material
Remaining

Field size different.

After ruling out metering problems, re-check geography.

Excessive gaps between applicator
passes.

Gap between opposing pass end trenches should be one
row space (e.g. 30in)

Material
Consumption
Too High

Field size different.

After ruling out metering problems, re-check geography.

Excessive overlap

Gap between opposing pass end trenches should be one
row space (e.g. 30in). Also check tracks for unintended
re-applications, particularly if relying on GPS mapping.

Tank or system Leak

Suspend application. Check for leaks.

Rows Not
Fertilized

Check for plugged row-unit tube

Stop application. Lift applicator and inspect tines.

No Fertilizer
Flow

Strainer plugged

Close all valves. Inspect strainer (page 119). Clean screen
as needed.

Material run-out

Check tank level.

Tines
plugging
frequently

Tine tips too low for coulter depth

Raise tine weldment (page 93).

Coulter blades too worn

Replace coulter blades.

Field too wet

Wait for drier conditions.

Applicator not level from front to rear Check applicator front-to-back level (page 37).

Tractor rocking backward during
stops, or lift sequence pushing tines
backward

Refine stopping and/or lifting technique to avoid reverse
coulter motion in ground.

Excessive
NH

3

loss to

atmosphere
(all rows)

Application depth too shallow

Check/adjust tractor hitch (page 37), lift-assist spacers
(page 38) and gauge wheel height (page 86).

Coulters set too deep; lifting tines

Reduce coulter depth to tine depth (page 93).

Insufficient sealing

Adjust sealers (page 99). Test running dry. Try multiple
settings on different rows at the same time if the adjustment
needed is not obvious.

Check applicator front-to-back level.

Application rate too high for soil or
weather conditions

Consult with agronomist on optimal rate and conditions.

Field speed too high

Slow down.

NH

3

loss to

atmosphere
(some rows)

Wings not level

Check tire pressures.

Check wings level (page 124).

Fold cylinders locked in Neutral, and
unable to follow terrain

Set fold/lift circuit to continuous Extend (unfold/lower) for
field application.

This manual is related to the following products: