beautypg.com

Great Plains YP3025A Operator Manual User Manual

Page 97

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

93

02/16/2012

Table of Contents

Index

401-705M

MetaData: End of “Important Safety Information
MetaData: End of “Troubleshooting

Air lines
plugging
between
Y-tube and
meter

Sag or kink in air hose.

Check air tube placement in tube mount weldment. If correct,
shorten any hose that has stretched due to age.

Meter is shut off but Y-tube is open.

Shut off Y-tube.

Air tube assembly not positioned on
correct tab.

Move assembly to properly position Y-tubes over row meters.

Sag in air hose due to incorrect
frame height

Raise or lower the tongue so center portion of frame is level
with gauge wheel area.

Hydraulic
marker
functioning
improperly,
or not at all

Marker/Fold switch set to Fold.

CFM Switch must be set to “Marker”. Set tractor remote cir-
cuit to Neutral or Float before operating switch.

Marker/Aux valve set to Aux

On a planter with optional Auxiliary Hydraulics, selector valve
must be set to Marker for markers to function. Set tractor
remote circuit to Neutral or Float before changing valve.

Air or oil leaks in hose fittings or con-
nections.

Check all hose fittings and connections for air or oil leaks.

Low tractor hydraulic oil level.

Check tractor hydraulic oil level.

Loose or missing bolts or fasteners.

Check all bolts and fasteners.

Needle valve(s) in sequence valve
plugged.

Open needle valves, cycle markers slowly and reset needle
valves, refer to page 164.

Marker disk
does not
mark

Marker folding linkage does not have
enough slack to allow marker disk to
drop into field depressions.

Maximum down float should be limited by the slot at the rod
end of the marker cylinder, refer to page 166.

Reverse marker disk to pull or throw dirt.

Auxiliary
Hydraulics
Inoperative

Marker/Fold switch set to Fold

CFM Switch must be set to “Marker” for Aux to function. Set
tractor remote circuit to Neutral or Float before switching.

Marker/Aux valve set to Marker

Selector valve must be set to Aux. Set tractor remote circuit
to Neutral or Float before changing valve.

Hydraulic
Hitch Won’t
Stay Raised

Bypass valve is open at hitch

Close valve.

Speed
Reading
Doesn’t
Match
Tractor

Monitor speed reading will only
match tractor with planter lowered

If speeds don’t agree during planting (with planter lowered),
re-calibrate radar speed sensor with planter lowered. See
page 167.

General Troubleshooting

Problem

Cause

Solution