103

02/16/2012

Table of Contents

Index

401-705M

Lift Cylinder Bleeding

Refer to Figure 119
1.

Unfold and lower planter.

2.

Un-pin rod ends of all lift cylinders. Position cylinders
so that rod ends may extend without striking
machine parts.

3.

Loosen the JIC fittings

at the base end of each

master lift cylinder.

4.

Extend the circuit until fluid appears at the loosened
fittings. Set circuit to Neutral and secure fittings.

5.

Loosen the JIC fittings

at the base end of each

slave lift cylinder.

6.

Extend the circuit until fluid appears at the loosened
fittings. Set circuit to Neutral and secure fittings.

7.

Re-pin rod ends.

Fold Cylinder Bleeding

Refer to Figure 120
1.

Begin with planter raised and lift cylinder locks
installed.

2.

Un-pin cylinder rod ends. Orient cylinders so that rod
ends may extend without striking planter parts.

3.

Loosen the JIC fittings

,

at the base end of all

cylinders.

4.

Extend the circuit until fluid appears at the loosened
fittings. Set circuit to Neutral and secure fittings.

5.

Loosen the JIC fittings

,

at the rod end of all fold

cylinders.

6.

Retract the circuit until fluid appears at all fittings. Set
circuit to neutral and secure fittings.

7.

Extend cylinders and re-pin cylinder rod ends.

Null4:

Figure 119

Lift Bleed

25227

1

2

1

2

1

2

Null4:

Figure 120
Fold Bleed

29808

3

1

2

4

1

3

2

4

1

2

3

4