TCP/IP MIB-II

2-33

ctIfPortPortNumber

ctIfPortPortNumber

{ctIfPortEntry 1}

This defines the port that is being described.

SYNTAX INTEGER

ACCESS read-only

STATUS mandatory

OBJECT IDENTIFIER: 1.3.6.1.4.1.52.4.3.3.3.1.1.1

The OID will actually be 1.3.6.1.4.1.52.4.3.3.3.1.1.1.X.Y where X is
the interface number and Y is the port requested. X will increment
from 1 to 28 (25 Ethernet, 2 Fast Ethernet, and the LCM port). Y
will always be 1 because there is only one port per interface. We
will always return a value of 1, because there is only one port on
the interface.

ctIfPortIfNumber

{ctIfPortEntry 2}

This defines the interface on which the port is being defined.

SYNTAX INTEGER

ACCESS read-only

STATUS mandatory

OBJECT IDENTIFIER: 1.3.6.1.4.1.52.4.3.3.3.1.1.2

The OID will actually be 1.3.6.1.4.1.52.4.3.3.3.1.1.1.X.Y where X is
the interface number and Y is the port requested. X will increment
from 1 to 28 (25 Ethernet, 2 Fast Ethernet, and the LCM port). Y
will always be 1 because there is only one port per interface. We
will return our port number, which will actually be the same as X.