TCP/IP MIB-II

2-5

ifPhysAddress

{ifEntry 6}

Physical Address Read-Write

1

The MAC address of the port. For the UART port, this field should
be an octet string of zero length.

ifAdminStatus

{ifEntry 7}

Integer Read-Write

The desired state of the port, i.e., one of the following:

• up (1) - setting the port’s state to up causes the port’s statistics to

be reset

• down (2) - the port is not to be used

• testing (3) - the port is to be put into local loopback (this value is

not saved if the unit reboots)

ifOperStatus

{ifEntry 8}

Integer Read-Only

The current status of the port, i.e., one of the following:

• up (1) - the port can send/receive NMS packets; however,

whether or not the port has its bridging functions enabled is
unknown.

• down (2) - the port is broken, or is intentionally physically

disabled.

• testing (3) - the port is in local loopback.

ifLastChange

{ifEntry 9}

TimeTicks Read-Only

The time, in centiseconds relative to sysUpTime, since the port
entered its last state (as defined by ifOperStatus).