401-832M

Seed Population Too High

Problem

Cause

Solution

Overall High
Population

Incorrect seed rate

Check seed rate charts

Ground Drive only: Incorrect Transmission
sprockets or shafts used

Check Transmission sprocket tooth counts and
Driver/Driven locations.

Ground Drive only: Incorrect Range
sprockets or shafts used

Check Range sprocket tooth counts and Driver/Driven
locations.

Finger Meter: Two seeds per finger
(doubles) due to seed too small.

Consult with dealer regarding alternate inserts.
Consider also switching to brush meters.

Finger Meter: Check carrier plate for wear.

Finger Meter: Check for weak finger
springs.

Brush Meter: Empty pockets on plates due
to matted brush.

Brush Meter: Two seeds per pocket on the
plates (doubles), due to pockets too large
for the seed

Select plates with smaller pockets.

False alarms or actual seed rate errors
due to monitor setup with incorrect row
count, spacing or active rows

When troubleshooting population issues, always first
rule out seed monitor setup. Review planter
configuration and monitor setup.

Incorrect cell count

Replace seed disks with correct disks, or reset rate for
current disks (if within range).

Improper gap on speed sensor.

Check speed sensor on planter for

1

16

inch to

1

8

inch

(1.6 to 3.2 mm) gap from wheel. Improper gap can
cause erratic speed signal causing monitor to falsely
report improper planting rate.

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor

manual.

Brush meter: Doubles due to incorrect
plates for crop or seed size

Use recommended plates for crop and seed size.

Sticky seeds: excess seed treatment

Increase seed lubricant.

High
Population,
One Wing

Ground Drive only: LH and RH Range
setup not matched.

Make sure LH and RH Range settings are identical, and
that sprockets are on proper DRIVING/DRIVEN shafts.

Ground Drive only: LH and RH
Transmission setup not matched.

Make sure LH and RH Transmission settings are
identical, and that sprockets are on proper
DRIVING/DRIVEN shafts.

High
Population,
Single Row

Incorrect seed plate with higher cell count. Install correct plate.

Brush Meter: Worn brushes allowing
excess seed to pass

Replace worn brushes.

This manual is related to the following products: