beautypg.com

Air system adjustments, Air system settings, Fan speed suggestions – Great Plains NTA2007HD Operator Manual User Manual

Page 86

background image

82

Great Plains Manufacturing, Inc.

Contents

Index

NTA607/2007HD

166-283M

Contents

Index

04/04/2011

Air System Adjustments

There are two adjustments for the air system:

1.

Fan rpm (this page),
which controls manifold air pressure, hopper air
pressure, and material delivery velocity.

2.

Inlet Manifold Diverter angle (page 84),
which controls the balance of air flow to each meter
on dual-hopper drills (whether single- or double-
shoot). This adjustment is not present on single-hop-
per drills.

There is no direct adjustment for hopper pressure. The
table figures are included for setting alarm limits in the
seed monitor. If a pressure alarm occurs, do not adjust
the fan or diverter to compensate. The cause is usually a
leak or a major blockage.

Fan Speed Suggestions

The specific fan rpm required varies considerably with
drill configuration, material density, application rate, field
speed and material properties. Develop and record set-
tings that are suitable for your operations.

Machine Damage Risk:
Always engage the fan with the tractor at a low engine speed.
Engaging the fan when the tractor is at high speed may cause
fan damage. Do not reverse hydraulic flow with the fan run-
ning.

At ideal fan speed:

• flow is more than high enough to avoid blockages

(from both meters on dual-hopper drills),

• flow is even across all hoses from each meter; and,

• flow is low enough to minimize seed cracking and

bounce.

Fan speed is monitored and reported by the seed moni-
tor, but is manually controlled.

If the fan cannot reach 3000 rpm, one or more hoses
may be mis-connected. Air moves toward the air box in
either rotation direction, but reverse spinning airflow is
too low to operate the system.

If the fan is operating properly, and at desired rpms, and
the diverter is correctly adjusted, but the pressure gauge
is out of limits, see “Magnehelic® Gauge Trouble-
shooting
” on page 103.

Air System Settings

Fan RPM

Limits

Minimum

Maximum

2000 rpm

to

4500 rpm

Typical Range

Minimum

Maximum

Milo

3250 rpm

to

4000 rpm

Soybeans

2750 rpm

to

3500 rpm

Sunflower

2250 rpm

to

3000 rpm

Wheat

3250 rpm

to

4000 rpm

Typical Range

Minimum

Maximum

12 in H2O

to

25 in H2O

30 cm H2O

to

64 cm H2O

30 kPa

to

64 kPa

3050 bar

to

6350 bar

4.4 psi

to

9.2 psi

Alarm Limits

Minimum

Maximum

1.3 kPa

to

8.6 kPa

130 bar

to

860 bar

13 cm H2O

to

88 cm H2O

0.19 psi

to

1.25 psi

5 in H2O

to

35 in H2O

31184

Manifold
Pressure

Hopper
Pressure
Limits

Null4:

Figure 67

Dual Manifold Pressure Gauges

31189

This manual is related to the following products: