Create a controlled material, Example non-preset material setup – Great Plains NTA2007HD Operator Manual User Manual
Page 73

Great Plains Manufacturing, Inc.
Adjustments
69
04/04/2011
166-283M
Create a Controlled Material
Re-define at least one material. Otherwise, create at
least one material. Some key steps:
1.
Type must be set to GRAN SEED CONTROL or
GRAN FERT CONTROL.
2.
Select or Disable: Preset Method
If using preset method, select initial rate increments
that are only a few percent, so as to have fine control
of the meter scale indicator. These can be changed
to coarser increments after calibration.
3.
Density must be accurately entered.
4.
#Outlets or #Towers is the number of outlets per
meter, and is always “4” for NTA607/2007HD,
whether single- or double-shoot.
5.
Enter the Cal Const if one is available for your seed
type. This value does not affect the calibration pro-
cess, and is replaced during calibration, but is useful
for comparison. The calibration constant developed
during calibration should be similar to the chart num-
ber.
6.
Set Variable Cal Const if one is available for your
seed. This is from a list of names pre-programmed
into the monitor software. It is usually not the same
name as the material name setup on page 68. In this
example, “Wheat 2S”, the “2S” refers to the (factory
standard) “2 star” meter flute configuration.
Pick a seed constant closest to yours in terms of
physical seed characteristics and meter flute config-
uration.
If a suitable Variable Cal Const is available, the sys-
tem can more accurately compensate for manual
calibration cranking speeds that differ from field rate.
If no suitable Variable Cal Const is available, set to
Disabled, and crank at an rpm near field speed at
step 36.
Example Non-Preset Material Setup:
MetaData: Wheat
MetaData: 2S
1-16
CH Wheat HRW
Comment
CHANNEL
1 or 2
Per meter
being config-
ured
Type
GRAN SEED CONTROL
or
GRAN FERT CONTROL
Must be one
of these
Units
Lb/ac with Rev/ac
Example
Preset
Method
Disabled
Example
Target Rate
60.0
LB/AC
Example
Max Rate
78.0
LB/AC
Upper + limit
Min Rate
48.0
LB/AC
Lower - limit
Inc/Dec %
1.0
%
Example
Density
60.00
LBS/BU
Example
#Towers
4
Cal Const
77591
Optional: Use
nearest chart
value
Variable Cal
Const
Wheat 2S
Optional
Shaft RPM
Low 10
High 50
RPM
Prod Level
Alarm
0
LBS
Seeds per
Pound
3000
S/LB
Example
High Pop
Alarm
20.0
%
Example
Low Pop
Alarm
20.0
%
Example
ROW
WIDTH
__
IN
Or use Auto-
Update Width
ON(-)/
OFF(X)
PATTERN
-------------------------
(unless tramline in use)
Row Fail
Rate
2 / 1
S/SEC
See ACC
manual