Material clean-outs – Great Plains NTA2007HD Operator Manual User Manual
Page 113
Great Plains Manufacturing, Inc.
Maintenance and Lubrication
109
04/04/2011
166-283M
Material Clean-Outs
For normal unloading of residual materials at completion
of planting, see “Unloading Materials” on page 108.
The present section covers completely cleaning out hop-
per and air system, when residues need to be minimized.
1.
Perform normal material unloading (page 108), then
fold and lock the drill (page 33) in preparation for a
move to a site suitable for wash-out.
2.
Reposition drill to a suitable site with rinse water and
hose available. This may be two different sites if
each hopper contained different materials.
If no otherwise suitable location is available, perform
a fertilizer or treated seed clean-out on an up-hill por-
tion of the field last planted or treated.
3.
Leave the tractor hitched, in Park with parking brake
set. If tractor cannot be left hitched, block drill tires or
set optional parking brakes.
4.
Deploy a ladder (page 42). Remove strainer
(page 44). Clean strainer. While strainer is removed,
inspect hopper for signs of problems that may pre-
vent normal clean-out, such as objects or congealed
masses too large to exit through meter (see “Prob-
lem Clean-Outs” on page 110).
5.
Install the calibration crank. Open both calibration
and clean-out doors on the meter of the hopper to be
cleaned out.
6.
Power wash the interior of the hopper while a second
person cranks the meters (page 52).
7.
Re-install strainer. Close lid tight and secure handle.
8.
After cleaning out the last hopper, close all doors.
Run air system for 10 minutes to blow moisture out
of meters and lines.
9.
Open all hopper meter doors. Run air for 5 minutes.
10. Shut off air. Clean door seals and meter box faces.
11. Close meter doors as for parking or storage. Move
drill to parking or storage site.
12. Follow normal Parking (page 62) or Storage
(page 63) instructions.
Review Regulations and Policies:
The steps at left apply when there are no specific clean-up
requirements provided by national, regional or local regula-
tion, nor by the seed and/or fertilizer supplier. Review any
legal requirements, instructions on the material containers,
and any Material Safety Data Sheets. Give priority to regula-
tions and supplier instructions. Modify the instructions here as
needed to comply.
Confined Space Hazard:
Do not enter hopper. Do not remove strainer (step 4) until
ready to clean strainer and wash-out hopper. Do not leave
strainer out after wash-out. Return the strainer to the hopper
and secure the hopper lid if the drill must be left unattended at
any time prior to step 7.