Great Plains NTA2007HD Operator Manual User Manual
Page 83

Great Plains Manufacturing, Inc.
Adjustments
79
04/04/2011
166-283M
37. Wipe all the material off the flanges around the
meter doors, on the chute, and capture that material
in the calibration bag.
38. Accurately weigh the calibration bag plus material. If
you set a “tare” on the scale, the reading is the
sample net weight, so skip step 39.
39. Subtract the empty container weight to determine
the application rate for
1
⁄
10
hectare (or
1
⁄
10
acre).
40. Press the Stop softkey
on the monitor
and enter the sample net weight (SampleWeight).
The monitor responds with a Calibration Constant.
Push the Save softkey
to accept this
value.
Calibration Closeout
41. Wipe the calibration door seals. Close the calibration
door(s). Raise and latch the chute. See page 46.
42. Re-install any removed final Range gears.
43. Remove and store the calibration crank.
Servo Seeding Example; Net Weight (step 39):
TotalWeight is 20.96 kg
for bag plus sample
BagWeight is 0.91 kg
SampleWeight is 20.96 - 0.91, which is:
20.96 kg
SampleWeight
TotalWeight
BagWeight
–
=