Tank lid operation – Great Plains NTA2007HD Operator Manual User Manual
Page 49
Great Plains Manufacturing, Inc.
Operating Instructions
45
04/04/2011
166-283M
Tank Lid Operation
Liquid fertilizer is customarily loaded from below the tank
via the quick-fill inlet, but may also be loaded from above
with the lid removed.
Do not open the lid while a quick-fill operation is already
in progress. The lid is vented, and will be releasing vapor
from the tank. At higher inlet rates, the tank may also be
mildly pressurized, and removing the lid could expose
you to sudden high concentrations of vapor.
Refer to Figure 38
Wear chemical gloves. The underside of the lid is likely to
be damp or wet, and coated with whatever chemicals
have been used.
Wear a mask or respirator. Consult the MSDS
a
for the
materials recently used, or material to be loaded.
Null4:
a. MSDS - Material Safety Data Sheet, available from the material supplier.
Null4:
Figure 38
Tank Lid Open
31390