Profile series v.g1.5 mortise dorm lock, 5 – installation of outside escutcheon assembly, 6 – installation of inside escutcheon assembly – SARGENT Profile Series v.G1.5 Mortise Locks User Manual
Page 9
Profile Series v.G1.5 Mortise Dorm Lock
Gasket
82-0500
1.
Connect green ground wire to terminal E3 (Fig. 1) and keypad
ribbon cable connector to back center of the controller (Fig. 2).
2.
Connect Motor Harness 6-pin connector to controller as shown
below (connector includes 2 motor wires and 2 deadbolt switch
wires). Then, attach the Inside Lever Monitor Switch Adapter
Harness as shown below.
NOTE: Connectors go on only one way. Do not offset connector.
Be sure they are completely seated.
6.5 – Installation of Outside Escutcheon Assembly
NOTE: For exterior applications, gasket (82-0500)
should be used to seal between escutcheon and
outside door surface
1A.
For 12- fire rated devices, feed keypad ribbon
cable connector and ground wire from outside
of door through gasket and fire stop plate hole;
then, through back side of conduit hole.
1B.
For non-12- exit devices, feed keypad ribbon
cable connector and ground wire through
gasket if used. Then, through conduit hole
in door.
2.
With outside lever horizontal, insert
mounting posts through door and
lock body. Make certain the lever
spindle is properly engaged in lock.
3.
Secure inside adapter and plate assembly by
threading screws into mounting posts of
outside lever assembly.
4.
Tighten retaining nut by hand, back off slightly
until star pattern lines up with square lever
assembly corners.
5.
Insert spindle into square hole of adapter plate.
6.6 – Installation of Inside Escutcheon Assembly
Mortise lockbody
connector
and wire
Ribbon Cable
and ground
wire through
back side of
conduit hole
Keypad ribbon
cable connector
Ground
wire
Ground
wire
Motor
Connector
Harness
From
Lockbody
Green
Ground Wire
from Outside
Escutcheon
Inside Lever
Monitor Switch
Adapter
Harness
(8-pin to 2-pin)
52-3412
Fig. 2
Fig. 1
Controller
Keypad Ribbon
Cable Connector
7
© SARGENT Manufacturing Company 2006, 2007
For installation assistance, contact SARGENT at 800-810-WIRE (9473)