1 A8094A
S1/S2 Replacement Controller Instructions
52-4424, 52-4425, 52-4426
FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com
Through-bolt Screws
1.
On the inside of the door, remove the battery cover’s security screw.
2.
Lift and remove the battery cover.
5.
Disconnect gray ribbon cables, green grounding wire,
motor harness, DPS harness, and hard-wired harness/PoE
(if present). Remove inside assembly from the door.
6.
Remove the four (4) Philips screws holding the original
controller in place. Remove controller.
This controller has been configured as a generic replacement.
The serial number MUST be changed before it can be used!
(For serial configuration see Step #12.)
Security Screw
3.
Remove inside lever (if present).
4.
Remove through-bolt screws on top and bottom of
escutcheon.
7.
Seat the controller into inside escutcheon. Attach with
the four (4) original Philips screws.