Mechanical installation, A) gate reset loop – Unitec Wash Select II POS Installation Manual User Manual
Page 62

W A S H
S E L E C T
I I
Document Number:
WS21001
56
Figure 21. Gate Position
3. Mechanical Installation
You will be installing the gate directly into the concrete slab. Mark the position of the
gate for conduit reference (see gate installation documentation), and then cut the gate
loops appropriately. You will need to run a conduit from the loop to the gate to hold
the gate loop leads. Conduit should be PVC only.
a) Gate Reset Loop
Each gate requires one gate reset loop. The gate reset loop should be 6’ long by 2.5’
wide. The loop should be positioned so that the edge closest to the approaching car
extends 2.5” beyond the forward edge of the gate arm. The loop should be positioned
at least 7.5” away from the gate as shown in the following figure.
Figure 22. Gate Reset Loop Dimensions
Document Title:
Wash Select II POS Installation Manual