beautypg.com

3 wash-fault, 5 wire the pos4000, 6 wiring 115 vac main power – Unitec Wash Select II POS Installation Manual User Manual

Page 25: Wash-fault, Wire the pos4000, Wiring 115 vac main power

background image

W A S H

S E L E C T

I I

Document Number:

WS21001

19

4.4.3 Wash-Fault

Some car wash manufactures include another interface signal to a unit, the WASH-FAULT
signal. This signal could have a voltage as high as 115VAC, and the installer is advised to
take the necessary precautions during installation.

1.

Locate the same connector to which the WIU signal is connected to in section
4.1.5 above, J-18 in the lower left corner of the CPU. The Wash-Fault Hot and
Wash-Fault Neutral are connected to pins 3 and 4 respectively as shown in the
table below.

Table 3. Wash-fault SIGNAL

Signal:

Wash Select II

CPU board

Location (lower

left corner):

Enterlink

Equivalent

POS4000,

E-system, Wash

Select V1

Equivalent

Wash-Fault Hot

J-18, Pin #3

N/A

N/A

Wash-Fault Neutral

J-18, Pin # 4

N/A

N/A

4.5 Wire the POS4000

If you have an optional POS4000 connection (Wash Select II POS) wire the communications
cable provided with the POS4000 as follows:

Table 4. POS4000 Connection

POS4000

Wash Select II

connector J22

Pin 1 – White

Pin 1 – White

Pin 2 – Red

Pin 2 – Red

Pin 3 – Black

Pin 3 – Black

Shield – Not
connected

Shield, strap to base
mounting bolt in case.

4.6 Wiring 115 VAC Main Power

There is a 3-Prong connector located in a socket on the Wash Select II main power supply
assembly (lower right-hand corner on back wall). It may be necessary to pull the coin hopper
out from its position in order to gain access to it. This is done by simply lifting up on the coin

Document Title:

Wash Select II POS Installation Manual