NOTE: The IDX coin-acceptor can be programmed to divert either the $1 coin or a
quarter. The diverted coin needs to be programmed to be on pin 6 of the IDX always.

The table below lists the programming structure.

Table 19. Canadian IDX Program Configuration

Number of Output

Pulses

IDX Rotary Switch

Position

Old Style with $1

coin Diverted

New Style with $1

Coin Diverted

Old Style $1
coin diverted

New Style
$1 Coin
Diverted

1

Token 1

Token 1

1-12, 14-255

2

Token 2

$2 Coin

1-255

8 on Coin 2

3

Token 3

$2 Coin

1-255

8 on Coin 2

4

$2 coin

$1 coin

8

1 on Coin 1

5

Quarters

$1 Coin

1

1 on Coin 1

6

$1 Coin

Quarters

1

1 on Coin 2


C R E D I T S E T U P

If you have the credit option, you need to decide whether you would like to do batch
closing and opening manually or automatically. Manual batch opening and closing
gives you the option of closing and opening batches at your own convenience, while
in auto batch opening and closing, the machine does it all automatically. In auto
mode, batch closing/opening happens once every 24 hours- at 11pm every night. If
you shut your machine down before 11 pm every night, the batch closing/opening
happens the next morning when you turn the machine back on again. If, on the other
hand, you don’t turn the machine off, but use either the WIU or Fault inputs to
pronounce “The carwash is out of service” condition overnight, machine will
close/open batches regardless at 11pm.

If you want to do batch opening/closing manually, do the following.

1.

Go to the setup menu, by turning the setup/operate switch to setup.

2.

Go to “Misc. setup” main menu.

3.

Select the “system time” sub menu and set the time to your current
standard time.

4.

Then go to the “credit systems” main menu.

5.

Go to the “credit systems” main menu in setup mode.

6.

Select “open batch”; batch should open. If batch opens, skip to step 8
below.

7.

If batch doesn’t open, cycle power to the entry stand, and try to repeat the
batch opening process.