7 testing the entry system, 8 testing the washes, Testing the entry system – Unitec Wash Select II POS Installation Manual User Manual
Page 41: Testing the washes
W A S H
S E L E C T
I I
Document Number:
WS21001
35
Document Title:
Wash Select II POS Installation Manual
Multi-Coin Acceptors:
If you have the multi-coin acceptor (IDX), and wish to program site-specific tokens, please
refer to the Operating manual for programming instructions.
5.7 Testing the Entry System
After performing the installation and programming, you must test the Wash Select II. Each of
the tests that follow is designed to test a specific aspect of the Wash Select II functionality.
Before testing the entry system, a few things must first be verified and/or completed.
If a proximity option is present, the infrared relay will have to be installed on the outer
surface of the main power supply, in its proper connector.
If speech option is present and the messages have not yet been recorded, they will
need to be. If the playback volume has not been set, it will also need to be.
If a modem, card reader, or thermal printer is installed as an option, it will require its
own testing prior to completing this portion. These and other tests can be found in the
Wash Select II Operations Manual.
1.
Verify 120 VAC power is available to the unit at the machine room circuit breaker.
2.
Verify that the unit is in “Operate Mode”, and that all of the programmed washes
appear in their proper display window, with every one of the backlights
illuminated.
3.
Place the unit into “Setup Mode”, and verify that the unit’s main customer display
indicates the menu item “Reports”. Scroll through these menu items, until
“Diagnostics” is displayed, and select that option.
4.
Under the “Diagnostics” sub-menu, you will find several test functions. Among
these is the capability of testing all standard components, and many optional
ones, such as card readers and thermal printers. Scroll through, and perform all
of the tests required under each menu topic that applies to your specific
installation.
5.
When all of the above diagnostics have been performed, troubleshoot any
problem areas, or proceed to the next section.
5.8 Testing the Washes
It is necessary to make sure that the connections between the PLC and the unit controller are
properly made and accurate. Purchasing all of the available wash types and by verifying that
the correct wash is given properly tests this connection. These steps should be performed on
all new Wash Select II installations. Prior to beginning, ensure that the toggle switch is placed
in the “Operate Mode”.
1.
Using any combination of $1s, $5s, & $10s, purchase all of the washes
advertised.