Unitec Wash Select II POS Installation Manual User Manual
Page 19
W A S H
S E L E C T
I I
Document Number:
WS21001
13
Document Title:
Wash Select II POS Installation Manual
2.
Set the unit onto the base, and align the four base holes to the pre-cut holes in
the Wash Select II. Use the remaining 4 bolts (with washers on) to secure the top
unit to the base. This is done by feeding the bolts through the holes in each of the
four corners in the bottom of the main cabinet, and then tightening with the 9/16 “
wrench.
3.
If the unit is to be wired into an existing or new security alarm system, the installer
will need to acquire the 2 spade terminal connectors, termination block, sticky
wire fasteners, and appropriate lengths of 22 AWG insulated wire.
Note: The alarm device connected to the switch must be a Class-2 device.
When wiring the switch, it is important to ensure that the terminal block is mounted to an
easily accessed, un-used, portion of the Wash Select II case. It should also be in close
proximity to the naturally occurring cable runs inside of the unit. This is done in order to easily
run security system wires to one common termination point, while still keeping a relatively
neat appearance. A good recommended routing method would be to secure the wires from
the terminals of the switch along the inside, top, left side of the Wash Select II case, and have
it continue down to the bottom, just underneath the bill stacker.
The terminal block can be mounted there, and then any wires that will be brought in from the
outside system can be pulled through the same wire shielding that connects the bill validator
to the main circuit board. This same shielding can be purchased and used to wrap the switch
wires.