PROBLEMS/SERVICE
FABRICATOR 211i
Manual 0-5157
5-3
PROBLEMS AND ROUTINE SERVICE
Components to be Tested
Minimum Insulation
Resistance (MΩ)
Input circuit (including any connected control circuits) to welding circuit
(including any connected control circuits)
5
All circuits to exposed conductive parts
2.5
Welding circuit (including any connected control circuits) to any auxiliary
circuit which operates at a voltage exceeding extra low voltage
10
Welding circuit (including any connected control circuits) to any auxiliary
circuit which operates at a voltage not exceeding extra low voltage
1
Separate welding circuit to separate welding circuit
1
Table 5-2: Minimum Insulation Resistance Requirements: Tweco Inverter Power Sources
C. Earthing
The resistance shall not exceed 1Ω between any metal of a power source where such metal is required to be
earthed, and -
1. The earth terminal of a fixed power source; or
2. The earth terminal of the associated plug of a transportable power source
Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring sup-
plying Tweco welding power sources should be inspected by a licensed electrical worker in accordance with
the requirements below -
1. For outlets/wiring and associated accessories supplying transportable equipment - at least once every
3 months; and
2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12 months.
D. General Maintenance Checks
Welding equipment should be regularly checked by an accredited Tweco Service Provider to ensure that:
1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly
connected and in good condition.
2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short
circuit.
3. The Welding System is clean internally, especially from metal filing, slag, and loose material.
E. Accessories
Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be
inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable
condition. All unsafe accessories shall not be used.
F. Repairs
If any parts are damaged for any reason, it is recommended that replacement be performed by an accredited
Tweco Service Provider.