PROBLEMS AND ROUTINE SERVICE

Components to be Tested

Minimum Insulation

Resistance (MΩ)

Input circuit (including any connected control circuits) to welding circuit

(including any connected control circuits)

5

All circuits to exposed conductive parts

2.5

Welding circuit (including any connected control circuits) to any auxiliary

circuit which operates at a voltage exceeding extra low voltage

10

Welding circuit (including any connected control circuits) to any auxiliary

circuit which operates at a voltage not exceeding extra low voltage

1

Separate welding circuit to separate welding circuit

1

Table 5-2: Minimum Insulation Resistance Requirements: Tweco Inverter Power Sources

C. Earthing

The resistance shall not exceed 1Ω between any metal of a power source where such metal is required to be

earthed, and -

1. The earth terminal of a fixed power source; or
2. The earth terminal of the associated plug of a transportable power source

Note that due to the dangers of stray output currents damaging fixed wiring, the integrity of fixed wiring sup-

plying Tweco welding power sources should be inspected by a licensed electrical worker in accordance with

the requirements below -

1. For outlets/wiring and associated accessories supplying transportable equipment - at least once every

3 months; and

2. For outlets/wiring and associated accessories supplying fixed equipment - at least once every 12 months.

D. General Maintenance Checks

Welding equipment should be regularly checked by an accredited Tweco Service Provider to ensure that:

1. Flexible cord is of the multi-core tough rubber or plastic sheathed type of adequate rating, correctly

connected and in good condition.

2. Welding terminals are in suitable condition and are shrouded to prevent inadvertent contact or short

circuit.

3. The Welding System is clean internally, especially from metal filing, slag, and loose material.

E. Accessories

Accessory equipment, including output leads, electrode holders, torches, wire feeders and the like shall be

inspected at least monthly by a competent person to ensure that the equipment is in a safe and serviceable

condition. All unsafe accessories shall not be used.

F. Repairs

If any parts are damaged for any reason, it is recommended that replacement be performed by an accredited

Tweco Service Provider.