Manual 0-5157

13. Process Selection Control

The process selection control is used to select the desired welding mode. Three modes are available, MIG (GMAW/

FCAW), LIFT TIG (GTAW) and STICK (SMAW) modes. Refer to section 3.18 or 3.19 for MIG (GMAW/FCAW) set

up details, section 3.21 for LIFT TIG (GTAW) set-up details or section 3.22 for STICK (SMAW) set-up details.

Note that when the unit is powered OFF the mode selection control will automatically default to MIG mode. This is

necessary so as to prevent inadvertent arcing should an electrode holder be connected to the unit and mistakenly

be in contact with the work piece during power up.

14. Digital Voltage Meter (Right Digital Display)

MIG Mode

This digital meter is used to display the pre-set (preview) Voltage in MIG mode and actual welding voltage of the

power source when welding. At times of non-welding, the digital meter will display a pre-set (preview) value of

Voltage. This value can be adjusted by varying the Multifunction Control Knob (10).

STICK and LIFT TIG Modes

This digital meter is used to display the Welding Output Terminal Voltage in STICK / LIFT TIG modes during non-

welding or welding. This value cannot be adjusted by varying the Multifunction Control Knob (10).
When welding, this digital meter will display actual welding voltage in all modes.

At the completion of welding, the digital meter will hold the last recorded voltage value for a period of approxi-

mately 10 seconds in all modes. The voltage meter will hold the value until; (1) any of the front panel controls are

adjusted in which case the unit will revert to preview mode, (2) welding is recommenced, in which case actual

welding amperage will be displayed, or (3) a period of 10 seconds elapses following the completion of welding in

which case the unit will return to preview mode.

NOTE

The preview functionality provided on this power source is intended to act as a guide only. Some differ-

ences may be observed between preview values and actual welding values due to factors including the

mode of welding, differences in consumables/gas mixtures, individual welding techniques and the transfer

mode of the welding arc (ie dip versus spray transfer). Where exact settings are required (in the case of

procedural work), it is recommended that alternate measurement methods be utilized to ensure output

values are accurate.

15. Gas Inlet (MIG mode only for MIG Gun or Spool Gun operation)

The Gas Inlet connection,5/8-18 UNF female thread is used to supply the appropriate MIG welding gas to the

Power Source. Refer to section 3.18 or 3.19 for MIG (GMAW/FCAW) set up details

!

WARNING

Only Inert Shielding Gases specifically designed for welding applications should be used.

16. ON / OFF Switch

This Single Phase circuit breaker performs a dual function.

It is used to turn the unit ON/OFF and it will also trip in the event of a fault.