INSTALLATION/SETUP

FABRICATOR 211i

Manual 0-5157

3-15 INSTALLATION/SETUP

WARNING

When the front digital displays are lit, the machine is connected to the Electricity Supply and the internal

electrical components are at Mains voltage potential.

17. Wiredrive Motor Circuit Breaker

The 4A Circuit Breaker protects the unit from electrical faults and will operate in the event of a motor overload.

NOTE

If a circuit breaker trips, a short cooling period must be allowed before an attempt is made to reset the unit

by pressing the circuit breaker reset button.

18. Local / Remote Switch (located in wirefeed compartment)

The local/ remote switch is used only when a remote control device (such as a TIG torch with remote current

control) is fitted to the unit via the remote control socket (item 9). When the local/ remote switch is in the remote

position, the unit will detect a remote device and work accordingly. When in the local mode, the unit will not detect

the remote device and will operate from the power source controls only. Note that the trigger will operate at all

times on the remote control socket irrespective of the position of the local/ remote switch (ie in both local and

remote modes).

Should a remote device be connected and the local/ remote switch set to remote, the maximum setting of the power

source will be determined by the respective front panel control, irrespective of the remote control device setting.

As an example, if the output current on the power source front panel is set to 50% and the remote control device

is set to 100%, the maximum achievable output from the unit will be 50%. Should 100% output be required, the

respective front panel control must be set to 100%, in which case the remote device will then be able to control

between 0-100% output.

19. Burnback Control (located in wirefeed compartment)

The burnback control is used to adjust the amount of MIG wire that protrudes from the MIG gun after the comple-

tion of MIG welding (commonly referred to as stick out). To decrease the burnback time (or lengthen the amount

of wire protruding from the MIG gun at the completing of welding), turn the burnback control knob anti-clockwise.

To increase the burnback time (or shorten the amount of wire protruding from the torch at the completing of

welding), turn the Burnback Control knob clockwise.

20. MIG Gun & Spool Gun Switch

The MIG Gun / Spool Gun switch is used to switch welding mode between MIG Gun functionality and Spool Gun

functionality

21. Cooling Fan

The Fabricator 211i is designed with an intelligent fan control. When the 211i is switched ON the cooling fan will

come ON for approximately 3 seconds then automatically switch the fan OFF. The cooling fan will remain OFF until

it is required for cooling purposes. This has two main advantages; (1) to minimize power consumption, and (2)

to minimize the amount of contaminants such as dust that are drawn into the power source.

Note in STICK mode the fan operates continuously.