2.09 Specifications
Description
Fabricator 211i Multi Process 3 in 1 Welder
Power Source Part No.
W1004200
Power Source Dimensions
H17.12" x W10.47" x D 24.29" (435mm x 266mm x D617mm)
Power Source Mass
57.3lb (26kg)
Cooling
Fan Cooled
Welder Type
Multi Process Welding System
Applicable Standard
CSA E60974-1-00 / UL60974-1 / IEC 60974-1
Number of Phases
Single Phase
Nominal Supply Voltage
208/230 VAC ± 10%
115VAC± 10%
Nominal Supply Frequency
50/60Hz
50/60HZ
Welding Current Range
MIG Mode
STICK Mode
TIG Mode
10-210 Amps
10-200 Amps
10-200 Amps
10-140 Amps
10-110 Amps
10-150 Amps
Wirefeed Speed Range
100 - 600 IPM
100 - 400 IPM
MIG Welding Voltage Range
14.5 - 24.5V DC
14.5 - 19V DC
Nominal OCV
70V DC
Effective Input Current (I
1eff
)
for MIG (GMAW/FCAW)
for STICK (SMAW)
for LIFT TIG (GTAW)
14.4A/11.2A
16.8A/15.8A
11.7A/11.5A
15.5A
17.8A
17.4A
Maximum Input Current (I
1max
)
for MIG (GMAW/FCAW)
for STICK (SMAW)
for LIFT TIG (GTAW)
32.2A/25.0A
33.6A/31.6A
23.3A/22.9A
24.5A
30.1A
29.4A
Single Phase Generator Requirement
7.5 kVA
*3.7 kVA
MIG (GMAW/FCAW) Welding Output, 104°F, 10 min.
210A @ 20%,24.5V
122A @ 60%, 20.1V
95A @ 100%, 18.8V
110A @ 45%,19.5V
99A @ 60%, 19.0V
77A @ 100%, 17.9V
STICK (SMAW) Welding Output,1040°F, 10 min.
200A @ 25%,28.0V
130A @ 60%, 25.2V
101A @ 100%, 24.0V
110A @ 35%,24.4V
90A @ 60%, 23.6V
70A @ 100%, 22.8V
TIG (GTAW) Welding Output, 104°F, 10 min.
200A @ 25%,18.0V
130A @ 60%, 15.2V
101A @ 100%, 14.0V
150A @ 35%,16.0V
115A @ 60%, 14.6V
90A @ 100%, 13.6V
Open Circuit Voltage
70 V
Protection Class
IP23S
Table 2-1: Fabricator 211i Specifications
Note 1: The Effective Input Current should be used for the determination of cable size & supply requirements.
Note 2: Motor start fuses or thermal circuit breakers are recommended for this application. Check local require-
ments for your situation in this regard.
Note 3: Generator Requirements at the Maximum Output Duty Cycle.
* Some 115 VAC, 15 amp/20 amps electrical outlets fitted with GFCI (Ground Fault Circuit Interrupt) protection
against a nuisance trip with this equipment due to worn or out of tolerance components in the GFCI. In such cases
have the 115 VAC, 15 amp/20 amp FGCI electrical outlet replaced by a qualified electrical trades person.