Section 4: operation, 01 power supply control panel, Section 4: operation -1 – Tweco 400 Ultra-Cut(October 2014) User Manual
Page 65: Power supply control panel -1
![background image](/manuals/595211/65/background.png)
ULTRA-CUT 100 XT/200 XT/300 XT/400 XT
Manual 0-5264
OPERATION
4-1
SECTION 4: OPERATION
4.01 Power Supply Control Panel
Art # A-11541_AB
AC Indicator
Temp Indicator
Gas Indicator
DC Indicator
A/
Status Indicator
A/
AC Power Lamp
Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via the
input contactor when the ON/OFF switch is in ON position.
TEMP Lamp: Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures
above normal limits. Let the unit cool before continuing operation.
GAS Lamp: Flashing during start up gas purge/pump priming, then steady whenever gas is flowing. Indicates
adequate gas pressure and coolant flow for operation.
DC Lamp: Indicates the power supply is generating output DC voltage.
A/
Status Indicator: Shows CCM code version on start up followed by the Current Control setting and
system status. Refer to Section 4.05 and Status Code Section for details.
Rear Panel AC Power Lamp
Indicates AC power is present inside the unit