ULTRA-CUT 100 XT/200 XT/300 XT/400 XT
Manual 0-5264
SPECIFICATIONS
2-3
Ultra-Cut 100 XT™ Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps) Wire (AWG)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
400
50/60
21
31
40-45
#12
4
Ultra-Cut 200 XT™ Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
400
50/60
42
62
100
#6
16
Ultra-Cut 300 XT™ Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps) Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
400
50/60
63
93
150
#4
25
IEC
400
50/60
72
106
150
#4
25
Ultra-Cut 400 XT™ Power Supply
Input
Power Input Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
400
50/60
93
137
200
#1
50
NOTE
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition pub�
lished by the National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord
of certain types rated for 75 deg C in a�bient te�peratures up to �0 deg C� Using wires of lower te��
deg C in a�bient te�peratures up to �0 deg C� Using wires of lower te��
C in a�bient te�peratures up to �0 deg C� Using wires of lower te��
perature rating or different insulation type �ay require larger wire size� De rate for higher a�bient�
These are suggestions only� Always refer to your local and national codes that apply to your region for
final determination of correct wire type and size.