APPENDIX 7: CNC
CNC functions
CNC I/O circuits provide at least 1000V galvanic isolation from the plasma power supply.
While the CNC circuits are isolated from the power supply, many of the signal returns on J15 and TB1, TB2 & TB3
are common to each other. J15 pins 1, 4, 5, 10, 17, and TB1-1, 5, 7, 9, and TB2-1 & 3 are all common. J15 pin 12 and
TB2-10 are also connected to the others when SW6 (OK to Move select) is set for voltage.
Rear Panel CNC Connector J15:
37 Circuit (Amp CPC) Remote Standard:
These are also duplicated on TB1, TB2 & TB3 use one or the other not both.
Chassis gnd (for SC-11 cable shield)
1
Start/Stop
3 (+); 4 (-)
Ok to Move (contacts or voltage 1)
12(-); 14 (+)
Divided Arc volts (selectable ratio
50:1; 40:1; 30:1; 16.6:1, 25:1)
5 (-); 6 (+)
PreFlow ON
7 (+); 9 (-)
Corner Current Reduction
10 (+); 11 (-)
Isolated Circuit Comm (for SC-11)
�
Chassis
Gnd
13
Keying
plug
15
Hold Start
16(+); 17 (-)
Plasma Mark
21 (+); 22 (-)
Cut Expanded Metal
23 (+); 24 (-)
CNC Plasma Enable2
25 (+); 26 (-)
Remote Analog Current Control 3
29 (+); 30 (signal); 31 (-)
Stop (Latched) SW4
32 (+); 33 (-)(comm.)
Pilot is ON (contacts)
34; 35
Spare
(contact)
36;