ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

7-4

TORCH INFORMATION

Manual 0-5264

CAUTION

The cartridge assembly must cover the O-Ring on the torch head.
Do not force the cartridge if it will not tighten fully. Remove the cartridge assembly and gently clean the

threads on the torch head with a wire brush. Apply oxygen-compatible lubricant (supplied with the torch)

to the threads.

Torch Head O-Ring

Torch Head

Art # A-07202

0.063 - 0.083"
(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

3. Slide the ohmic clip over the shield cup if using ohmic torch height control sensing.

NOTE

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically

with the ohmic sensing circuit.

Ohmic Clip

Art # A-03393_AB

4. Connect the wire lead from the height finder to the ohmic clip.