beautypg.com

Tweco 15XC CE Merlin PAK User Manual

Page 48

background image

OPERATION

3 - 14

Manual 0-2529

Four two-pole DIP switches located on the control logic PC
board control the auto-restart functions.

Auto-Restart

(continued)

Auto-Restart

SW1-1

SW1-2

Mode

Position

Position

Normal

0

(Off)

0

(Off)

Disabled

0

(Off)

1

(On)

1

(On)

0

(Off)

1

(On)

1

(On)

On/Off (SW1)

Note:

Either pole set to 1(on)

disables auto-restart function

Auto-Restart

SW2-1

SW2-2

Mode

Position

Position

Normal

0

(Off)

0

(Off)

Delayed

0

(Off)

1

(On)

1

(On)

0

(Off)

1

(On)

1

(On)

Pre-Flow Time

SW3-1

SW3-2

(Seconds)

Position

Position

2

0

(Off)

0

(Off)

4

0

(Off)

1

(On)

7

1

(On)

0

(Off)

10

1

(On)

1

(On)

Post-Flow Time

SW4-1

SW4-2

(Seconds)

Position

Position

1.25

0

(Off)

1

(On)

2.5

0

(Off)

0

(Off)

5

1

(On)

0

(Off)

10

1

(On)

1

(On)

Post-Flow Time

SW4-1

SW4-2

(Seconds)

Position

Position

5

0

(Off)

1

(On)

10

0

(Off)

0

(Off)

20

1

(On)

0

(Off)

40

1

(On)

1

(On)

Normal/Delayed (SW2)

Note:

Either pole set to 1(on)

sets auto-restart function

Pre-Flow Delay (SW3)

Post-Flow Delay (SW4)

For Hand Cutting

Systems (A1845-01)

with 19x704 Logic PCB

Post-Flow Delay (SW4)

For Machine Cutting

Systems (A1845-15)

with 19x910 Logic PCB