Repairs
CAUTION: Abuse of Module After Failure
If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to
correct the fault by a physical impact to the housing. An internal relay may have failed in such a man-
ner that its replacement is required.
If the Module is not immediately replaced or repaired, multiple simultaneous failures may accumu-
late such that the safety function can not be guaranteed.
Do not attempt any repairs to the Module. It contains no field-replaceable components. Return it to the factory for warranty
repair or replacement, as follows.
Contact Banner Factory Application Engineering at the address listed on
. They will attempt to troubleshoot
the system from your description of the problem. If they conclude that a component is defective, they will issue a return merchandise
authorization (RMA) number for your paperwork, and give you the proper shipping address.
Pack the Module carefully. Damage that occurs in return shipping is not covered by warranty.
Specifications
Power
Supply Voltage and Current
24V ac/dc, 50-60 Hz, no polarity
AC: 24V +10% / -15%
DC: 24V ±10%
Power Consumption
approx. 4VA/2.5 W
Performance
Startup Reset Time
1.5 seconds
Hysteresis
6% typical
Inputs
Input Requirements for PNP Input Sensors
PNP Input Sensors: 24V dc (terminals S1s and S2s)
Input current min.: 3 mA Input current max.: 25 mA
Min. pulse time: 1 ms ON, 1 ms OFF
Max. IPM at Inputs S1s and S2s
30,000
Adjustable Setting Ranges (impulses/minute)
SSM-FM-11A10: 5…40 ipm, 35…340 ipm, 300…2,700
ipm, or 1,200…10,500 ipm
SSM-FM-11A20: 10…80 ipm, 80…650 ipm, 600…
5,300 ipm, 2,400…20,000 ipm
Outputs
Standstill (under-speed) Output Response Time
See formula
Over-speed Output Response Time
SSM-FM-11A10: Range 5…10,500: tR = 700 ms typ.
SSM-FM-11A20: Range 10…20,000: tR = 350 ms typ.
Switching Capacity to AC 15
3A / 230V ac for N.O. contacts (per IEC/EN 60
947-5-1)
Output Configuration
Outputs K1 & K2: two redundant (total of four) safety
relay N.O. (forced-guided) contacts—AgNi, gold flash-
ed; one auxiliary N.C. contact—AgNi, gold flashed
Contact ratings (all N.O. and N.C. output contacts): 2
normally open (N.O.) output channels and 1 normally
closed (N.C.) aux. output
Current Rating:
SSM-FM-11A... Safe Speed Monitoring Modules
P/N 140782_web
rev. C