beautypg.com

System installation, Warning, Caution. . . shock hazard – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 37

background image

P/N 68413 rev. A

35

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

System Installation

Dual-Channel

Safety Stop Circuit

Single-Channel

Safety Stop Circuit

NOTE:
See pages 33-34
for explanation
of single- and
dual-channel stop
circuits

* Installation of transient suppressors across the coils of FSD1

and FSD2 is recommended. NOTE: Do not exceed OSSD
maximum load capacitance specification.

1) See Section 3.5 for more

information on Reset input and
hookup.

2) See Section 3.7.3 for information

on EDM input and hookup.

3) TEST input must be jumpered if

not used. Typically a Normally
Open switch held closed. See
Section x.x for information on
TEST input and hookup.

+24V dc

0V dc

Reset

PE 1

dc Com 2

+24V dc 3

(Not Used) 4

RESET 5

EDM1 6

EDM2 7

OSSD1 8

OSSD2 9

EZ-SCREEN

Receiver

(1)

(2)

*

*

FSD

1

FSD

2

+

+

Figure 3-19. EZ-SCREEN receiver generic hookup – FSD (2-channel EDM, key reset)

WARNING . . .

Proper Wiring

The generalized wiring 

configurations shown are provided only 
to illustrate the importance of proper
installation .
The proper wiring of the EZ-SCREEN
System to any particular machine is
solely the responsibility of the
installer and end user.

PE 1

dc Com 2

+24V dc

+24V dc

0V dc

3

TEST2 4

or

TEST1 5

(Not Used) 6

+24V dc 7

dc Com 8

PE 9

EZ-SCREEN

Emitter

Auxiliary power
connections
(see Section 3.5)

Open to test

(1)

1) TEST input must be

jumpered if not used.
Typically a Normally Open
switch held closed. See
Section 3.7.4 for
information on TEST
input and hookup.

Figure 3-18. EZ-SCREEN emitter generic hookup

CAUTION. . .

Shock Hazard

Always disconnect all

power from the EZ-SCREEN System
and the guarded machine before
making any connections or replacing
any component.
 Use extreme caution 
to avoid electrical shock at all times. 
Serious bodily injury or death could
result.

WARNING . . .

OSSD Interfacing

To ensure proper

operation, the EZ-SCREEN OSSD 
output parameters and machine input
parameters must be considered when 
interfacing the EZ-SCREEN solid-state 
OSSD outputs to machine inputs.
Machine Control circuitry must be
designed so that the maximum load 
resistance value is not exceeded and 
that the  maximum specified OSSD 
OFF-state voltage does not result in an 
ON condition.
Failure to properly interface the
OSSD outputs to the guarded
machine could result in serious
bodily injury or death.