beautypg.com

System installation – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 19

background image

P/N 68413 rev. A

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

System Installation

Sensing Mode Configurations

In opposed-mode configuration, the emitter and receiver are 

mounted opposite from each other to form a single beam (see

Figure 3-3). Opposed-mode configuration can be combined with 

vertical corner mirrors for perimeter-guarding applications, as 

shown in Figure 3-4 and described in Section 3.3.6.

Access-Guard Configurations

In access-guard configuration, the emitter and receiver are 

used with two angled mirrors to create multiple beams from one 

EZ-SCREEN Point System – in effect, forming a vertical light 

grid using one beam. The ACCESS-GUARD kit is available for 

constructing this configuration (see Figure 3-3 and Section 2.1).

Figure 3-3. EZ-SCREEN Point sensing mode configurations

Two-Beam Opposed-Mode
configuration

Emitter

Receiver

Receiver

Emitter

Receiver

Emitter

ACCESS-GUARD configuration set too far apart and misaligned can result in

voids in the sensing area. Path A is unintended.

ACCESS-GUARD configuration

Receiver

Emitter

Intended Path

Path A

Emitter

Emitter

Receiver

Emitter

Receiver

Mirror #2

Mirror #1

Single opposed mirror leaves

dangerous voids in the sensing area

Both emitters facing the same

direction provides crosstalk potential

Unacceptable Configurations

Receiver