beautypg.com

Chapter 5 maintenance, Inspection and cleaning 3129 digital display fuses – Bird Technologies 3129 Display User Manual

Page 57

background image

41

Chapter 5

Maintenance

This chapter contains cleaning, troubleshooting, specifications, and part infor-
mation for the Bird Broadcast Power Monitor and the 3129 Digital Display.

Inspection and Cleaning

This unit requires only simple and routine maintenance.

1.

Wipe off dust and dirt regularly. Use a soft, clean cloth dampened with mild
detergent.

2.

Check connectors, connector pins, and cables for damage. If needed, clean
the connectors using a self-drying contact cleaner that leaves no residue.

3129 Digital Display Fuses

The 3129 Digital Display contains two time-delayed IEC (5 x 20mm) Type T 1.0A,
250V fuses. These are the only user replaceable parts. Refer to figure Figure 29
on page 42 f
or fuse location.

WARNING

Disconnect the unit from the RF power source and the ac

line before any disassembly. The potential for electrical

shock exists.

CAUTION

Do not use harsh or abrasive detergents for cleaning.

This manual is related to the following products: